View:
hybridization incubator, 120V

HB-3D Hybrigene

  • Temp Range from 10°C above ambient to 80°C
  • Can hold up to 16 mini or 4 large glass tubes
  • Flexibility at an affordable price, offering excellent temperature accuracy and uniformity
  • The Hybrigene is a compact, stackable alternative to the Hybridiser HB-1D - for when space is important
  • Stack up to 3 ovens, saving on valuable laboratory space

    Technical Specifications

    Specification

    HB-3D Hybrigene

    Maximum glass tube capacity

    16 mini tubes

    Maximum temperature

    80°C

    Minimum temperature

    10°C above ambient

    Adjustable rotation speed

    0, 5 to 20 rpm

    Adjustable rocking platform

    5-20 or 15-60 opm

    Stability in chamber

    1.0°C

    Stability in tubes

    ±0.1°C

    Uniformity in chamber

    ±1.5°C

    Uniformity in tube

    ±0.5°C

    Temperature set point resolution

    0.1°C

    Absolute accuracy

    ±0.3°C

    Dimensions L x W x H (mm)

    355 x 383 x 432

    Voltage

    230V, 50-60Hz

    Power

    750W

    Shipping Weight

    21kg

Item#:
FHB4DP
Your Price:
3601.50
Each

Order #

Capacity (Cu.Ft.)

Max Temp (°C)

Wattage

Amps

Inside Dimensions (in.) (WxHxD)

Outside Dimensions (in.) (WxHxD)

Shipping Weight (lbs.)

10AF

0.6

225

800

6.95

12x8.62x10

14x20.5x12

50

20AF

1.14

225

1000

8.69

13x11.625x13

15x24.5x15

66

30AF

1.83

225

1600

13.91

18x14.625x12

20x28.5x14

82

40AF

2.86

225

1600

13.91

18x19.625x14

20x33.5x16

112

Warranty: 18 months

Item#:
ASAIRFOROVEN

The HB-500 Minidizer is a personal, desktop hybridization oven that is ideal for use in laboratories with low use and limited space requirements. Microprocessor controls allow for consistent, repeatable results and the chamber interior is stainless steel with a 3/8" beta-blocking acrylic cover. The cover swings down for direct access to the bottle carousel, which can be removed from the chamber for the easy insertion or removal of bottles.

In addition to the hybridization oven features mentioned above, the Crosslinker In 95-0031-01 features:
·  Preset and manual controls for ultraviolet or time exposures
·  Preset exposure delivers 120,000 microjoules or five minutes of exposure
·  Shortwave 254nm, 8 watt, ultraviolet tubes
·  Microprocessor measures and controls UV output, ensuring maximum energy efficiency
·  Large LED display continuously displays time or energy settings
·  Tactile membrane switch keypad
·  Window on the door allows viewing of the process yet blocks out the UV radiation
·  Dimensions: 17.5W x 24H x 15D in. (445 x 610 x 381 mm)
·  1 year warranty


Variable Speed

10 to 18 RPM

Heating Element

1200 Watts

Operation Range

Ambient to 99.9oC

Temperature Controller Accuracy

+0.1OC

Temperature Display

LED

Temperature Stability

Inside Oven: +0.3oC to 68oC
Inside Bottles: +0.1oC to 68oC

Temperature Uniformity

Inside Oven: +0.1oC to 68oC
Inside Bottles: +0.1oC to 68oC

Interior Dimensions

14"W x 10.75"H x 10.75:D 
(356 x 273 x 273mm)

Bottle Capacity

Twenty (20) 35 x 150 mm
Ten (10) 35 x 300 mm
Four (4) 70 x 300 mm 
(with separate Carousel Kit)

Power

12V AC/DC from 115V/60Hz or 230V/50Hz

Crosslinker Specifications (HL-2000 HybriLinker only)

Pre-set or user-selected UV energy or UV time exposure settings

Maximum UV energy setting of 999,900 microjoules per cm2

LED displays time or energy

Internal interlocking safety system

Tactile membrane switch keypad

Five 8-watt, 254nm shortwave dual bipin discharge type tubes

Interior Dimensions: 11"W x 3.7"H x 11.5" D (280 x 95 x 292mm)

Item#:
ASHYBRIOVEN3

ProBlot 12 Hybridization Oven Now Only $2,900!

See LabValues 2002 details - Here 
 
 
Item H1200A - Use promo code 2LV-1.22 for discounted pricing - Valid through December 31, 2022
This promo cannot be combined with other promotions or discounts.  Institutional pricing not valid. All terms apply.   

 

ProBlot™ Hybridization Ovens/Shakers

  • Two models for medium to high throughput
  • Precise temperature control and stability for reproducible results
  • Variable speed and adjustable axis rotisseries
  • Optional rocking platform and additional rotisseries

The ProBlot 6 and 12 meet the needs of medium to high throughput laboratories with their 6 and 12 bottle capacity.

The rotisserie and incubation system in the ProBlot ovens provides the perfect conditions for consistent results with low background. Mechanical convection creates an extremely uniform environment by circulating air through the chamber while heat input is controlled by a microprocessor. An integral viewing area in the door allows for sample visualization without disrupting the interior temperature. The desired agitation level is obtained with the variable speed and adjustable axis rotisserie.

Oven chambers are corrosion resistant stainless. ProBlot 6 and 12 have a grounded interior electrical outlet for powering small equipement. The ovens are provided with a rotisserie for 35 mm diameter bottles and 50 ml disposable tubes, a drip tray, two large bottles and a pack of hybridization mesh. A rocking platform and other rotisseries are available.
 

Specifications 

 

ProBlot™ 6
(H0600A) 

ProBlot™ 12
(H1200A) 

Bottle Capacity

6 large | 12 small

12 large | 24 small

Rotisserie/Rocker Speed

4 to 20 rpm

4 to 20 rpm

Temp Range

Amb. +5° to 80°C

Amb. +5° t to 80°C

Temperature Control

Microprocessor

Microprocessor

Temp. Resolution/Uniformity

0.1°C/0.5°C

0.1°C/0.5°C

Exterior Dimensions
(W x D x H)

19 x 17.5 x 19.5 in.

19 x 17.5 x 19.5 in.

Chamber Dimensions
(W x D x H)

14.5 x 11 x 13.5 in.

14.5 x 11 x 13.5 in.

Weight

59 lb | 26.8 kg

59 lb | 26.8 kg

Electrical*

120 V~, 60 Hz

120 V~, 60 Hz


*Other voltages available upon request.
Item#:
ASHYBRIOVEN1

Operational Features

  • Microprocessor PID control
  • Simple calibration and auto-tuning function
  • Temperature control: 15°C above ambient to 250°C
  • Delayed ON/OFF digital timer range: 1 min ~ 99 hr 59 min
  • Intuitive and easy-to-operate control panel with bright LED display (1°C resolution) and touch-sensitive keypad
  • High temperature limit setting and open door alert
  • Convenient presetting function for 3 most commonly used temperature settings
  • RS-232 interface


Constructional Features

  • Gravity flow convection for uniform sample heating
  • Fully insulated dual-wall door with 180 degree hinges and a pull-down handle
  • Rounded inner chamber corners for easy cleaning and optimal airflow
  • Corrosion-resistant incoloy sheath heating element and stainless steel interior
  • Adjustable dual slide vents for controlling inner vapor circulation (diameter: 38mm/1.5")
  • Threefold tempered-glass window providing clear inside view of the chambers (optional)
Model ON-02G ON-12G ON-22G
Chamber Vol (L/cu ft) 52 / 1.8 91 / 3.2 135 / 4.8
Temperature Range (°C/°F) Amb. +15 to 250 / Amb. +27 to 482
Fluctuation1)(±°C/°F)at 100°C
0.3 / 0.54
Variation1)(±°C/°F)at 100°C
5.9 / 10.62
7.5 / 13.5
6.9 / 12.42
Dimension Interior dimensions
(W x D x H) (mm/inch)
400x360x365
/ 15.7x14.2x14.4
480x410x465
/ 18.9x16.1x18.3
610x460x485
/ 24.0x18.0x19.0
Exterior dimensions
(W x D x H) (mm/inch)
577x542x760
/ 22.7x21.3x30.0
657x592x870
/ 25.9x23.3x34.3
785x642x897
/ 30.9x25.3x35.3
Net weight (Kg/lbs) 49 / 108 59 / 130 68 / 150
Electrical Requirements (230V) 50/60Hz, 4.3A 50/60Hz, 6.0A 50/60Hz, 7.4A
Cat. No. AAH11135K AAH11145K AAH11155K
Electrical Requirements (120V) 50/60Hz, 6.7A 50/60Hz, 8.3A 50/60Hz, 10.0A
Cat. No. AAH11136U AAH11146U AAH11156U

1) Technical data (according to DIN 12880)

 

Item#:
ASNATCONOVEN1

Series FD-S Solid.Line | Drying and Heating Chambers with Forced Convection

Benefits

  • Easy handling
  • Accurate temperature control
  • Simple and ergonomic door opening

Important characteristics

  • Temperature range: ambient temperature +10°C to 250°C
  • APT.line™ preheating chamber technology
  • Forced convection
  • Adjustable exhaust air flap
  • Controller with timer function
  • 1 chrome-plated rack, incl. shelf supports
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm

The new products in the Solid.Line impress with their tried-and-tested BINDER quality and reliability. They are suited to drying and heating. The attributes of the Solid.Line are geared towards the application in question and therefore used in research and quality assurance.


Specifications

Item No.

9090-0019

9090-0025

Model

FD-S 56

FD-S 115

Housing Dimensions*
(W x H x D)

24.19 x 24.63 x 22.73 in.

30.1 x 28.96 x 24.27 in.

Internal Dimension
(W x H x D)

15.76 x 17.34 x 12.21 in.

21.67 x 21.67 x 13.79 in.

Net Weight

79 lbs

117 lbs

Interior Volume

1.9 Cu Ft

3.7 Cu Ft

*Housing dimensions do not include fittings and connections

Operational Features Microprocessor PID control Simple calibration and auto-tuning function Temperature control: 15°C above ambient to 220°C Delayed ON/OFF digital timer range: 1 min ~ 99 hr 59 min Intuitive and easy-to-operate control panel with bright LED display (1°C resolution) and touch-sensitive keypad High temperature limit setting and open door alert Convenient presetting function for 3 most commonly used temperature settings Corrosion-resistant incoloy sheath heating element and stainless steel interior Adjustable dual slide vents for controlling inner vapor circulation (diameter: 38mm/1.5") Model ON-01E ON-11E ON-21E Chamber Vol (L/cu ft) 52 / 1.8 100 / 3.5 150 / 5.3 Temp Range(°C/°F) Amb. +15 to 220 / Amb. +27 to 428 Fluctuation1)(±°C/°F)at 100°C 0.3 / 0.54 0.4 / 0.72 0.5 / 0.9 Variation1)(±°C/°F)at 100°C 6.5 / 11.7 4.1 / 7.38 7.3 / 13.14 Dimension Interior dimensions (W x D x H) (mm/inch) 375x370x370 / 14.8x14.6x14.6 455x430x510 / 18.0x17.0x20.0 585x460x555 / 23.0x18.1x21.9 Exterior dimensions (W x D x H) (mm/inch) 530x535x737 / 20.9x21.1x29.0 610x595x877 / 24.0x23.4x34.5 740x625x922 / 29.1x24.6x36.3 Net weight(Kg/lbs) 34 / 75 46 / 101.4 59 / 130 Electrical Requirements (230V) 50/60Hz, 4.3A 50/60Hz, 6.0A 50/60Hz, 7.4A Cat. No. AAH15015K AAH15025K AAH15035K Electrical Requirements (120V) 50/60Hz, 6.7A 50/60Hz, 8.3A 50/60Hz, 10.0A Cat. No. AAH15016U AAH15026U AAH15036U 1) Technical data (according to DIN 12880)
Item#:
ASNATCONOVEN
Shake 'N' Bake Model

Applications:

  • Hybridization and wash procedures for scientists that prefer to use heat sealed bags, plate or dishes/trays
  • Conventional incubations with or without rocking motion
  • Cell culture in bags

Features:

  • Gentle rocking motion is perfect for washes and hybridization
  • Small footprint saves bench space
  • Three removable shelves, each capable of holding blots up to 20cm x 20cm
  • Gasket sealed metal and acrylic plastic see through door
  • PID controller for easy temperature selection and stability
  • Adjustable rocking speed from 8 to 25 strokes per minute
  • Temperature up to 70°C
  • Supplied with three removable shelves. Please note: Total maximum shelf load is 1 kg (2.2 lb.)
  • The Shake 'n' Bake has a 2 year warranty
Temp Range Ambient +5°C to 70°C
Temperature Stability 0.5°C at 65°C (within chamber)
0.25°C at 65°C (within sample vessel)
Exterior Dimensions 12.5"W x 14.5"D x 16"H
Interior Dimensions 11.5"W x 11.5"D x 10.5"H
Removable Tray Dimensions 8.5"W x 8"D x 0.5"H
Electrical 115V / 60Hz
Warranty Two Years Parts & Labor
Item#:
136400
Your Price:
3123.16
Each

FD Series Standard Features:

  • Temp Range: room temperature plus 5 °C to 300 °C
  • APT.line preheating chamber technology
  • Forced convection
  • Adjustable exhaust air flap
  • Controller with timer functions
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Other voltages available upon request.

 FED Series Standard Features:

  • Adjustable fan speed
  • Controller with LCD display (Avantgarde.Line) with enhanced timer functions
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Class 2 integrated independent adjustable temperature
  • Safety device (DIN 12880) with visual alarm
  • USB port for recording data
  • Other voltages available upon request.

 

Technical Data of the Series FD and FED

Description

FD 23

FD 56

FD 115

FED 56

FED 115

Basic data

 

 

 

 

 

Housing dimensions not incl. fttings and connections

20

60

115

60

116

W x H x D [mm]

435 x 495 x 520

560 x 625 x 565

710 x 735 x 605

560 x 625 x 565

710 x 735 x 605

Interiors dimensions W x H x D [mm]

222 x 330 x 300

400 x 440 x 345

550 x 550 x 385

400 x 440 x 345

550 x 550 x 385

Performance Data Temperature

 

 

 

 

 

Temp Range ... [°C] above ambient temperature to [°C]

300

300

300

300

300

Temperature uniformity at 150 °C [± K]

2.5

1.7

1.7

1.4

1.2

Temperature fluctuation at 150 °C [± K]

0.3

0.3

0.3

0.3

0.3

Heating-up time to 150 °C [min]

25

15

20

15

20

Recovery time after 30 seconds door open at 150 °C [min]

6

5

5

5

5

Energy consumption at 150 °C [Wh/h]

290

340

290

340

Item#:
ASSTDINC1

BENEFITS

  • Uniform drying conditions thanks to APT.line technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

IMPORTANT CHARACTERISTICS:

  • Temp Range: room temperature plus 5 °C to 300 °C
  • APT.line preheating chamber technology
  • Free convection
  • Adjustable exhaust air flap
  • Controller with timer functions
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Other voltages available upon request.

 

Technical Data of the Series ED

9010-0192

9010-0334

9010-0336

Description

ED 23

ED 56

ED 115

Basic data

Housing dimensions not incl. fttings and connections

20

57

114

W x H x D [mm]

435 x 495 x 520

560 x 625 x 565

710 x 735 x 605

Interiors dimensions W x H x D [mm]

222 x 330 x 300

360 x 420 x 380

510 x 530 x 425

Performance Data Temperature

Temp Range ... [°C] above ambient temperature to [°C]

300

15-300

8-300

Temperature uniformity at 150 °C [± K]

2.8

2.5

2.0

Temperature fluctuation at 150 °C [± K]

0.5

0.4

0.4

Heating-up time to 150 °C [min]

28

45

60

Recovery time after 30 seconds door open at 150 °C [min]

28

25

20

Energy consumption at 150 °C [Wh/h]

180

250

Item#:
ASOVEN

Series ED-S Solid.Line | Drying and Heating Chambers with Gravity Convection

Benefits

  • Easy handling
  • Accurate temperature control
  • Simple and ergonomic door opening

Important characteristics

  • Temperature range: ambient temperature +7 °C to 250 °C
  • APT.line™ preheating chamber technology
  • Natural convection
  • Adjustable exhaust air flap
  • Controller with timer function
  • 1 chrome-plated rack, incl. shelf supports
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm

The new products in the Solid.Line impress with their tried-and-tested BINDER quality and reliability. They are suited to drying and heating. The attributes of the Solid.Line are geared towards the application in question and therefore used in research and quality assurance.


Specifications

Item No.

9090-0015

9090-0021

Model

ED-S 56

ED-S 115

Housing Dimensions*
(W x H x D)

24.19 x 24.63 x 22.73 in.

30.1 x 28.96 x 24.27 in.

Internal Dimension
(W x H x D)

15.76 x 17.34 x 13.79 in.

21.67 x 21.67 x 15.37 in.

Net Weight

79 lbs

117 lbs

Interior Volume

2.2 Cu Ft

4.2 Cu Ft

*Housing dimensions do not include fittings and connections

Drying/heating chambers w/

BENEFITS

  • Uniform drying conditions thanks to APT.line technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

Important characteristics:

    • Temp Range: 60 °C to 230 °C
    • Adjustable exhaust air flap
    • Hydro-mechanical thermostat
    • Class 1 temperature limitation device (Modell E028-230V-T)
    • Timer 0 â 120 min
    • 2 chrome-plated racks
    • Other voltages available upon request.

    Specifications

    Designation

    E028-120V¹

    Option model

    Standard

    Order number

    9010-0106

    Performance Data Temperature

    Temp Range [°C]

    60-230

    Heating-up time to 150 °C [min]

    36

    Recovery time after 30 seconds door open at 150 °C [min]

    19

    Electrical data

    Rated Voltage [V]

    120

    Power frequency [Hz]

    60

    Nominal power [kW]

    0.8

    Phase (Nominal voltage)

    1~

    Measures

    Interior Vol [L]

    28

    Net weight of the unit (empty) [kg]

    22

    permitted load [kg]

    25

    Load per rack [kg]

    10

    Measures - Doors

    Unit doors

    1

    Measures - Internal Dimensions

    Width [mm]

    400

    Height [mm]

    280

    Depth [mm]

    250

    Measures - Outer dimensions

    Width net [mm]

    580

    Height net [mm]

    405

    Depth net [mm]

    425

    Wall clearance back [mm]

    160

    Wall clearance sidewise [mm]

    100

    Fixtures

    Number of shelves (std./max.)

    2/4

    1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series.
Item#:
9010-0106
Your Price:
1289.02
Each
View: