S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Cold Storage
Looking for cold storage freezers or other cold storage equipment to protect your important samples? You’ll find what you need right here.
When it comes to cold storage, MIDSCI offers a truly vast collection; one item of which is sure to be precisely what you’re looking for. From refrigeration to liquid nitrogen and every temperature in between, we have a solution for storing your laboratory samples and reagents.
Our lab freezers include: refrigerator/lab freezer combo products, upright freezers, under-counter freezers, chest lab freezers, and enzyme/vaccine lab freezers.
Our refrigeration equipment offers various options, depending on the model you choose: superior temperature stability, cycle defrost, Energy Star compliance, and highly durable interiors and exteriors.
Our cryogenic storage options boast an immense offering for storage of anywhere from a couple hundred to 100,000 samples!
We have plenty of other cold storage equipment items that can reliably and safely store anything you need to.
Haier Transport Coolers
Transportation units for blood banks, blood collecting stations and transporting biological products such as blood, medicines, samples and reagents.
Z & ZA Units:
- Optimized semiconductor cooling to maintain the temperature inside the cabinet between 2 to 6° after being powered up.
- 4° ice rafts for accumulation of cold to effectively increase the cooling area and extend the holding time.
- Power supply supporting wide voltage zone, 12V conversion and vehicle mounting. Camera monitoring to automatically identify whether there are stormed items inside the cabinet so as to prevent them from being left behind.
- Storage security is enhanced with NFC swipe card module, lock/unlock status information is uploaded in real-time. Magnetic lock has authorization software and user permissions allow unlocking by scanning the QR code to provide security for the stored items.
- ZA units are equipped with cold chain monitoring module and temperature and humidity. Displays data in real-time and information is uploaded to the cloud platform for query through the Wi-Fi or 4G module. GPS positioning allows users to query the movement and track the transport cooler in real time. Bluetooth printing function allows users to print records simply with the touch of one. Camera monitoring to automatically identify whether there are stored items in the cooler to prevent stored items from left in error.
B Units:
- Passive cooling mode is possible by placing the case in a freezer.
- PCM ice pack can be placed inside to keep storage temperature at 2 to 10°C during transportation.
- ABS interior for additional insulation value.
Biomedical Refrigerator and Freezer Combo
- Intelligent Microprocessor with Digital Display
- Natural Hydrocarbon Refrigerant
- Audible and Visual Alert with Remote Alarm
- Contact Self-closing Door with Magnetic Gasket
- Padlock to Secure Safe Storage
- Stainless Steel Interior
- One cabinet with two independent chambers, both are self-contained and independently controlled with individual doors
- Refrigerator chamber is equipped with a double-paned glass viewing window and LED interior lighting
Environment Friendly
- Hydrocarbon refrigerant (R600a for refrigerator / R290 for freezer) and CFC-free polyurethane insulation for reduced global warning potential
Stainless Steel Interior
- The interior of refrigerator and freezer are both made of stainless steel, which is easy to clean and corrosion-proof
Microprocessor Controller with Digital Display
- Refrigerator temperature 2~8°C with resolution of 0.1°C
- Freezer temperature -40~-10°C with resolution of 1°C
- Multiple alarm functions with remote alarm contact to ensure safe monitoring
High Performance
- Refrigerator: Forced-air cooling system with cycle defrost, temperatureuniformity±3°C
- Freezer: Cold wall cooling system, manual defrost, temperature uniformity±5°C
- Standard USB port & optional printer, easy to get temperature record
Haier Combined Refrigerator and Freezer
Temperature Control- Refrigerator temperature ranges from 2°C to 8°C.
- Freezer temperature ranges adjustable from -10°C to -40°C
- Microprocessor temperature control accuracy 0.1°C (refrigerator) and 1°C (freezer)
- Separate doors for refrigerator and freezer with independent lock catches, dual padlocks available to ensure product safety.
- Multiple alarm functions including high or low temperature, sensor error, high ambient temp, power failure and remote alarm.
- Two types of alarm indications: audible buzzer and visible flashing light.
- Refrigerator and freezer have independently controlled variable frequency refrigeration systems, standalone displays as well as separate on and off controls.
- Robust compressor system operating with environmentally friendly hydrocarbon refrigerant.
- Refrigerator with high quality and high efficiency cooling fan provides better temperature uniformity and stability.
- Large LED screen display for excellent user interface experience.
- USB port automatically saves temperature data for up to 10 years for convenient inquiry and record keeping.
- Optional printer to simultaneously print out temperatures of the refrigerator and the freezer.
- Four casters and two levelling legs design for ease of maneuvering.
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
STABILITY² (CABINET AIR) | +/- 1.1°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
ENERGY CONSUMPTION | 1.32 KWH/DAY |
AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Stainless Steel Automatic Defrost Freezer
- Manual Defrost
- 115v, 60 Hz, 6 Amps, 1/3 Hp
- Ul/c-ul Listed
- Shipping Weight: 462 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: -15°c to 25°c
- Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
Stainless Steel Built-In Vaccine Refrigerator
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
STABILITY² (CABINET AIR) | +/- 1.2°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Premier Countertop Auto Defrost Freezer Freestanding
- Width: 23 ¾"
- Depth: 24”
- Height: 20 "
- Auto Defrost
- 115v, 60 Hz, 1 Amp,1/8 Hp
- Ada Compliant
- Ul/c-ul Listed
- Shipping Weight: 106 Lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms, With Battery Back Up
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Glycol Bottle
- Adjustable Operating Temperature Range: 5°f to -13°f (-15°c to -25°c)
- Auto Defrost Cycle Every 6 Hours:
- Max Air Temp in Empty Freezer: 4.34°c
- Max Air Temp in Loaded Freezer: -2.89°c
- Max Sample Temp in Empty Freezer: -4.76°c
- Max Sample Temp in Loaded Freezer: -9.58°c
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
456 Pharmacy Solid Door Refrigerator
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
STABILITY² (CABINET AIR) | +/- 1.1°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
ENERGY CONSUMPTION | 1.32 KWH/DAY |
AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Standard Pharmacy Solid Door Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Shipping Weight: 227 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
- Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low-temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
Freestanding Premier Pharmacy/Vaccine Countertop Refrigerator
- Width: 17 ¼”
- Depth: 19 ¼”
- Height: 21 ¼”
- Cycle Defrost
- 115v, 60 Hz, .90 Amps, 1/8 Hp
- Energy Consumption 0.71 Kwh/day
- Ul/c-ul Listed
- Shipping Weight: 91 Lbs.
- Energy Star Certified
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
Refrigerator and Freezer (-40°C Operation) Combination
- Exterior Dimensions:23 3/4" W X 24"D X 65"H
- Note: This Unit Must Have 4” Clearance on Sides and Back for Adequate Ventilation
- Manual Defrost (Freezer); Cycle Defrost (Refrigerator)
- 115v, 60 Hz
- 2.2 Amps, 1/4 Hp (Freezer); 1.3 Amps, 1/6 Hp (Refrigerator)
- Ul/c-ul Listed
- Shipping Weight: 268 Lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Remote Alarm Contacts
- Adjustable Operating Temperature Range- Freezer:-37°c – -43°c; Refrigerator: 2°c to 8°c
Refrigerator and Freezer (-40°F Operation) Combination
- Width: 23 3/4"
- Depth: 24"
- Height: 65"
- Note: This Unit Must Have 4” Clearance on Sides and Back for Adequate Ventilation
- Manual Defrost (Freezer); Cycle Defrost (Refrigerator)
- 115v, 60 Hz
- 2.2 Amps, 1/4 Hp (Freezer); 1.3 Amps, 1/6 Hp (Refrigerator)
- Ul/c-ul Listed
- Shipping Weight: 268 Lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Remote Alarm Contacts
- Adjustable Operating Temperature Range- Freezer: -35°f to -45°f (-37°c to 43°c); Refrigerator: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm