Lab Refrigerators

Reliably store your priceless content with our lab refrigeration equipment.

 

Safely store irreplaceable samples, and protect the performance of your reagents, with MIDSCI’s dependable and innovative lab refrigeration equipment.
 
Our wide range of lab refrigeration equipment is guaranteed to meet your laboratory research, testing, and storage needs thanks to an extensive selection of possible features, such as:

  • Low-E double-pane thermal glass for superior temperature stability.
  • Attention-grabbing alarms and digital displays that mitigate perilous temperature variations.
  • Non-peel/non-chip vinyl exteriors, heavy duty PVC coated wire shelves, or NSF approved white aluminum interiors with 300 series stainless steel flooring for augmented durability.
  • Cycle defrost that keeps regular maintenance to a minimum and frees up your time.
  • Energy Star technology that minimizes your power consumption expenses.
  • CFC-free 134A refrigerant for enhanced environmental friendliness
ArcticTemp Chromatography Refrigerator

ArcticTemp Chromatography Refrigerator

Shop Now

Under the counter Refrigerator

Under the counter Refrigerator

Shop Now

ArcticTemp Glass Door Refrigerator

ArcticTemp Glass Door Refrigerator

Shop Now

|◀ 13 - 24 of 67 ▶|
View:

Glass Door Freestanding Vaccine Refrigerator


These premier undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.

These glass door freestanding refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.
*-one or more of these certifications may apply to this unit.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER TUBE AND GRID CONSTRUCTION,   FANLESS
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 1.4°C
 STABILITY² (CABINET AIR) +/- 1.3°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.7°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 6 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.67 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 41 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 36 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA
Item#:
ASGLDOFRVACR

Built-In Pharmacy Stainless Steel Undercounter Refrigerator

 
The Pharmacy Premier Built In  Undercounter Refrigerators feature a microprocessor temperature controller and display, which allows for precise temperature control, verification and recovery versus mechanical style thermostats.
     
The Built-In models are designed with a "front breathing" ventilation system, eliminating the need for clearance around the top and sides of the unit; enabling the user to incorporate these units into cabinets and other applications where free space is limited.
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines. 

  • Width: 23 ¾"
  • Depth: 24 ½”
  • Height: 33 3/8"
  • Cycle Defrost
  • 115v, 60 Hz, 1/8 Hp, 1.74 Amps
  • Ul/c-ul Listed
  • Energy Star Certified
  • Shipping Weight:  137lbs.
  • Microprocessor Temperature Controller
  • Digital Temperature Display
  • Audible and Visual High and Low Temperature Alarms
  • Remote Alarm Contacts
  • 2 Probes; 1 in Air and 1 in Sample Bottle
  • Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm


Item#:
ASBIPHSTSTEUNREF

Glass Door Stainless Steel Pharmacy Refrigerator


The Premier Pharmacy Stainless Steel Refrigerators feature a microprocessor temperature controller, allowing for precise temperature control, recovery and maintenance versus mechanical style thermostats.
Critical samples and supplies are security backed with an extensive package of temperature security and alarm features. 
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines. 

  • Cycle Defrost
  • 115v, 60 Hz, 3 Amps, 1/5 Hp
  • Etl Listed
  • Shipping Weight: 356 Lbs.
  • Microprocessor Temperature Controller
  • Digital Temperature Display With Battery Back-up to Support Temperature Monitoring and Alarms
  • Audible and Visual High and Low Temperature Alarms
  • Remote Alarm Contacts
  • 2 Probes; 1 in Air and 1 in Sample Bottle
  • Adjustable Operating Temperature Range: 36°f to 46°f
Item#:
ASGDSTSTPHR

Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456


These premier undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
These solid door freestanding refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.
\The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A, PROPANE
 CONDENSER TUBE AND GRID CONSTRUCTION,   FANLESS
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 1.4°C
 STABILITY² (CABINET AIR) +/- 1.3°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.7°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.5°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 6 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.67 KWH/DAY (315 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 41 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 42 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA
Item#:
ASSODRVRCNA456

Standard Pharmacy Glass Door Refrigerator


The Pharmacy Standard Glass Laboratory Refrigerators are purpose built for scientific and medical applications.  Standard Series Glass Door Laboratory Refrigerators feature a digital microprocessor temperature controller allowing for the precise temperature management necessary for critical samples and supplies.  A forced air directional refrigeration system provides superior temperature uniformity and recovery after door openings.

The temperature display and alarm module offers product security with a monitoring and alarm system.  Real-time sample simulated temperatures are constantly displayed and supported by audible/visual high and low temperature alarms. 
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Cycle Defrost 
  • 115v, 60 Hz, 3 Amps, 1/5 Hp 
  • Etl Listed 
  • Microprocessor Temperature Controller
  • Digital Temperature Display
  • Audible and Visual High and Low Temperature Alarms
  • Remote Alarm Contacts
  • 2 Probes; 1 in Air and 1 in Sample Bottle
  • Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
Item#:
ASSTPHGLDOREF

Premier Pharmacy Glass Door Refrigerator


Pharmacy Premier Series Refrigerators are Large Capacity Refrigerator Units for High Volume Pharmacies. Standard features include a microprocessor temperature controller and display for superior temperature control, verification, and recovery. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. An extensive package of audible and visual alarms is provided to protect critical samples and vaccines.
The temperature display and alarm module offers an array of robust security features with a monitoring and alarm system that is 100% independent of a microprocessor temperature controller for additional product security. 
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Cycle Defrost
  • 115v, 60 Hz, 3 Amps, 1/5 Hp
  • Etl Listed
  • Shipping Weight: 258 Lbs
  • Microprocessor Temperature Controller
  • Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
  • Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
  • Sample Simulated Digital Temperature Display; .1° Resolution
  • Adjustable Temperature Display in Celsius or Fahrenheit
  • Audible and Visual High/low Temperature Alarms
  • 2 Probes; 1 in Air and 1 in Sample Bottle

Item#:
ASPRPHGLDORE

Freestanding Pharmacy Undercounter Refrigerator


The Pharmacy Premier Built In  Undercounter Refrigerators feature a microprocessor temperature controller and display, which allows for precise temperature control, verification and recovery versus mechanical style thermostats.
     
The Built-In models are designed with a "front breathing" ventilation system, eliminating the need for clearance around the top and sides of the unit; enabling the user to incorporate these units into cabinets and other applications where free space is limited.
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines

  • Cycle Defrost
  • 115v, 60 Hz, 1/8 Hp, 1.74 Amps
  • Ul/c-ul Listed
  • Energy Star Certified
  • Shipping Weight:  137lbs.
  • Microprocessor Temperature Controller
  • Digital Temperature Display
  • Audible and Visual High and Low Temperature Alarms
  • Remote Alarm Contacts
  • 2 Probes; 1 in Air and 1 in Sample Bottle
  • Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
Item#:
ASFRPHUNR

Haier Transport Coolers

Transportation units for blood banks, blood collecting stations and transporting biological products such as blood, medicines, samples and reagents.

Z & ZA Units:

  • Optimized semiconductor cooling to maintain the temperature inside the cabinet between 2 to 6° after being powered up.
  • 4° ice rafts for accumulation of cold to effectively increase the cooling area and extend the holding time.
  • Power supply supporting wide voltage zone, 12V conversion and vehicle mounting. Camera monitoring to automatically identify whether there are stormed items inside the cabinet so as to prevent them from being left behind.
  • Storage security is enhanced with NFC swipe card module, lock/unlock status information is uploaded in real-time. Magnetic lock has authorization software and user permissions allow unlocking by scanning the QR code to provide security for the stored items.
  • ZA units are equipped with cold chain monitoring module and temperature and humidity. Displays data in real-time and information is uploaded to the cloud platform for query through the Wi-Fi or 4G module. GPS positioning allows users to query the movement and track the transport cooler in real time. Bluetooth printing function allows users to print records simply with the touch of one. Camera monitoring to automatically identify whether there are stored items in the cooler to prevent stored items from left in error.

B Units:

  • Passive cooling mode is possible by placing the case in a freezer.
  • PCM ice pack can be placed inside to keep storage temperature at 2 to 10°C during transportation.
  • ABS interior for additional insulation value.
Item#:
ASTRANSCOOL
Premier 456 Pharmacy Solid Door Refrigerator

These premier upright refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
These solid door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency. 

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R290, PROPANE
 CONDENSER FIN AND TUBE DESIGN, HIGH EFFICIENCY   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 1.0°C
 STABILITY² (CABINET AIR) +/- 1.1°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.7°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 6.5 MIN.
 ENERGY CONSUMPTION 1.32 KWH/DAY
 AVERAGE HEAT REJECTION 2.21 KWH/DAY (315 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 49 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 30 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA
Item#:
ASP456PHSD

Stainless Steel Built-In Vaccine Refrigerator


These premier built-in undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
The stainless steel Refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER HYBRID FIN AND TUBE WITH LOW NOISE   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 0.8°C
 STABILITY² (CABINET AIR) +/- 1.2°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 4.8 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.57 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 43 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 35 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

 
Item#:
ASSSBIVR

456 Pharmacy Solid Door Refrigerator

 
These standard upright refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
These glass door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R290, PROPANE
 CONDENSER FIN AND TUBE DESIGN, HIGH EFFICIENCY   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 1.0°C
 STABILITY² (CABINET AIR) +/- 1.1°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.7°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 6.5 MIN.
 ENERGY CONSUMPTION 1.32 KWH/DAY
 AVERAGE HEAT REJECTION 2.21 KWH/DAY (315 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 49 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 30 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA
 
Item#:
AS456PHSODOR

Standard Pharmacy Solid Door Refrigerator


Pharmacy Premier Series Refrigerators are Large Capacity Refrigerator Units for High Volume Pharmacies. Standard features include a microprocessor temperature controller and display for superior temperature control, verification, and recovery. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. An extensive package of audible and visual alarms is provided to protect critical samples and vaccines.
The temperature display and alarm module offers an array of robust security features with a monitoring and alarm system that is 100% independent of a microprocessor temperature controller for additional product security. 
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Cycle Defrost
  • 115v, 60 Hz, 3 Amps, 1/5 Hp
  • Etl Listed
  • Shipping Weight: 227 Lbs.
  • Microprocessor Temperature Controller 
  • Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c) 
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
  • Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
  • Sample Simulated Digital Temperature Display; .1° Resolution 
  • Adjustable Temperature Display in Celsius or Fahrenheit 
  • Audible and Visual High/low-temperature Alarms 
  • 2 Probes; 1 in Air and 1 in Sample Bottle
Item#:
ASSTANDPHSODR
|◀ 13 - 24 of 67 ▶|