Pall® AcroPrep™ Advance 96-well Filter Plates
| Quantity | Price |
| 1 | 3362.91 |
STAT FAX 3300 Biochemistry Analyzer
Stat Fax® 3300 is designed for the processing of biochemistries, tube method immune assays, and drug assays from human serum, plasma, or urine. A removable flowcell installs in the read well to provide extremely rapid fluid sampling with low carryover. A builtin vacuum pump and an external waste bottle with level sensing are supplied standard. When the Flowcell is removed, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes. The design of the instrument includes many features to minimize operator error, such as stable factory calibration, automatic zeroing, complete operator prompting, detailed labeling, pre-programmed calculations, visual and audible
feedback, flags and error messages, minimal maintenance requirements. Test parameters, and standard curves are stored in memory for later recall. The Stat Fax® 3300 will store up to 120 tests in memory to be recalled for later use and allows for creation of Levey-Jennings plots for QC. In addition, it will store 512 Patient Results, 512 Control Results, 20 Patients on Worklist, and 15 tests per patient.
SPECIFICATIONS: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 3.5 (flow-cell mode) |
|
|
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
|
|
Stability: |
Drift of no more than 0.005A in 8 |
hours/bichromatic |
|
|
|
Light Source: |
Tungsten Halogen, 10 Watt, with |
automatic lamp saver |
|
|
|
Standard Wavelengths: |
340, 405, 505, 545, 580, and 630nm |
alternate filters available from 330 to |
|
750nm; an eight position filter wheel is optional |
|
|
|
Filter Type: |
IAD hardcoat interference, 10nm half |
Bandpass |
|
|
|
Tube Size: |
12mm round is standard |
|
|
Minimum Sample Volume: |
1mL for 12mm round tube |
250uL for flowcell |
|
|
|
Display: |
240x128 Graphic LCD w/ Backlight |
|
|
Printer: |
Thermal dot matrix with graphic capability |
Power Requirements: |
Auto-Switching Power Supply |
|
|
Voltage source: |
90 – 264 VAC |
|
|
Certifications: |
CE |
|
|
Speed: |
Reads, calculates and prints results, 3 |
seconds per tube |
|
|
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Index Mode |
|
|
|
Test Storage: |
Stores 120 tests. Stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges rate |
|
timing, standard values, test names, and |
|
previous standard curve. |
|
|
|
Dimensions: |
40cm (L) x 37 cm (W) x 14 cm (H) lid |
closed (30 cm lid opened), 14 lbs (6.4 kg) |
|
PNPLATEREAD

| SKU Number | # of Wells | Pore size | Filter Media | Qty | Price | Quantity | Add to Cart |
| 8022 | 96-Well [350 µL] | 0.8 µm | Mustang Q | 10/pk |
312.12
Each
|
||
| 8029 | 96-Well [350 µL] | 0.45 µm | Supor | 10/pk |
208.44
Each
|
||
| 8039 | 96-Well [350 µL] | 1.2 µm | Supor | 10/pk |
208.44
Each
|
||
| 8071 | 96-Well [350 µL] | 0.8 µm | Mustang Q | 10/pk |
306.72
Each
|
||
| 8072 | 96-Well [350 µL] | 0.8 µm | Mustang S | 10/pk |
306.72
Each
|
||
| 8130 | 96-Well [1 mL] | 0.45 µm | Supor | 5/pk |
125.28
Each
|
||
| 8171 | 96-Well [1 mL] | 0.8 µm | Mustang Q | 5/pk |
198.72
Each
|
||
| 8172 | 96-Well [1 mL] | 0.8 µm | Mustang S | 5/pk |
198.72
Each
|