Home  >  Equipment  >  Centrifuges  >  Mini Microcentrifuges  > PR1MA 8 Mini Microcentrifuge

PR1MA 8 Mini Microcentrifuge

Item #: ASMINCEN1008 

2 year warranty

Technical Data:    
     
Specifications GCM-24 GCM-R-24
Maximum Speed 15,000 rpm (200-15,000 rpm),
10 rpm increment
15,000 rpm (200-15,000rpm),
10 rpm increments
Maximum RCF 21,380 x G, (10 x G Increment) 21,380 x G, (10 x G increments)
Speed Accuracy +/- 20 rpm +/- 20 rpm
Temperature N/A -20°C to 40°C
Rotor Capacity Twenty-Four (24) 1.5 / 2.0 mL tubes Twenty-four (24) 1.5 / 2.0 mL tubes
Run Time 30 sec - 99 min or continuous 30 sec - 99 min or continuous
Power 5A, 500W 10A, 400W
Acceleration Time 25 Seconds 25 Seconds
Braking Time 25 Seconds 25 Seconds
Dimension (W x D x H) 280 x 364 x 266 mm
(11.0 x 14.3 x 10.5")
338 x 580 x 324 mm
(13.3 x 22.8 x 12.8")
Weight 12 Kg (26.5 lbs) 30 Kg (66.1 lbs)
Certifications CE, cTÜVus, FCC, MCA CE, cTÜVus, FCC, MCA
Warranty 2 Years 2 Years

Microcentrifuge Accessories:

GCM-24-AD2:  Rotor Adapters for GCM-12, GCM-24, GCH-24 for 0.2mL Tubes, 24/bag

GCM-24-AD5:  Rotor Adapters for GCM-12, GCM-24, GCH-24 for 0.5mL Tubes, 24/bag

GCM-24-5MLR:  Rotor for use with GCM-24 Series, 15000rpm max, 18-Place for 5mL Tubes

GCM-24-5ML:  Rotor for use with GCM-24 Series, 15000rpm max, 12-Place for 5mL Epp*

GCM-24-05ML:  Rotor for use with GCM-24 Series, 15000rpm max, 36-Place, for 0.5mL MCTs

GCM-24-PCR:  Rotor for use with GCM-24 Series, 15000rpm max, 4 x 8 positions for 0.2mL PCR Tubes

GCM-24-AD52:  Rotor Adapters for GCM-24-05ML Rotor for 0.2mL Tubes, 36/bag

GCM-AD2:  Rotor Adapter for use with GCM Series for 0.2mL MCT Tubes, 8/bag

GCM-AD5:  Rotor Adapter for use with GCM Series for 0.5mL MCT Tubes, 8/bag

 

PVC Cell Counting System

TPP's Packed Cell Vol (PCV) tube enables a quick and reproducible method of cell counting based on cell Vol. A quick centrifuge of the cell suspension pipetted into a PCV tube reveals a packed cell pellet in the PCV capillary, which can be easily read with the aid of an Easy read ruler. This non-subjective method is superior to old-fashioned and labor intensive hemacytometer based counting.

Functional Features:

  • Cell suspension sample can be directly quantitated without dilution
  • Multiple samples can be assayed simultaneously
    • Load and spin as many PCV tubes as your centrifuge rotor holds
  • Quick and reproducible
    • Cells can be spun down in 1 minute at 2500xg

Ergonomic Features:

  • Reproducible measurements
    • Graduated capillary model offers immediate quantitation
    • For finer quantitation: The Easy Read Ruler  is used with non-graduated PCV tubes
  • Eliminates expensive automated counters / fragile slides
    • Avoids subjective microscope counting

Quality Assurance:

  • Gamma-sterilized, DNAse/RNAse-Free, and pyrogen-Free
  • Individually wrapped in peel-off plastic wrapper

Protocol Example:

  • Uniformly mix cell suspension collected from TPP  flask/dish/bioreactor
  • Pipet 1000µL of cell suspension into a PCV tube
  • Spin multiple samples for 1 minute at 2500xg in a standard microcentrifuge
  • Record pellet Vol and compare to pre-generated standard curve of cell numbers to packed cell Vol.
    • Standard curve needs to be set up only once per cell line
    • Pipet pre-determined cell suspension Vols (dilutions) into a hemacytometer
    • Calculate and record the number of live cells for each concentration
    • Pipet the identical Vols into the PCV tube, centrifuge and record the numeric in the capillary that corresponds to pellet Vol
    • Plot the hemacytometer readings vs. the PCV readings for each Vol
    • This Standard Curve doesn't need to be redone for the same cell line and moving forward the cell suspension harvested from TPP flasks/dishes/plates only need to be centrifuged in PCV tubes and assayed for cell pellet measurements

High density of cells

    • With a very high density of the cells, the samples must not be diluted. You might simply reduce the sample Vol. Samples from the same series should be treated accordingly. 
    • For bacteria measurement the parameters have to be adjusted, for example higher g-force, smaller Vol, etc.
    • Micro centrifuges with swing-out rotors are preferable.

     

    Order#

    Description

    Quantity

    TP87005

    PCV Cell Counting Tubes (with capillary graduations only)

    50/pk

    TP87007

    PCV Cell Counting Tubes (no graduations)

    50/pk

    TP87008

    TPP Cap for PCV Tubes

    50/pk

    TP87010

    Easy Read Ruler

    1

    Please call us for sample!

 
 
SKU Number Capacity Speed Type of Centrifuge Price Quantity Add to Cart
MF8-B 8 x 1.5/2.0 mL or 32 x 0.2 mL Tubes or 4 x PCR 6,000 rpm Mini Microcentrifuge - Blue Lid
324.21
Each
MF8-C 8 x 1.5/2.0 mL or 32 x 0.2 mL Tubes or 4 x PCR 6,000 rpm Mini Microcentrifuge - Clear Lid
324.21
Each
MF8-G 8 x 1.5/2.0 mL or 32 x 0.2 mL Tubes or 4 x PCR 6,000 rpm Mini Microcentrifuge - Green Lid
324.21
Each
MF8-P 8 x 1.5/2.0 mL or 32 x 0.2 mL Tubes or 4 x PCR 6,000 rpm Mini Microcentrifuge - Purple Lid
324.21
Each
MF8-R 8 x 1.5/2.0 mL or 32 x 0.2 mL Tubes or 4 x PCR 6,000 rpm Mini Microcentrifuge - Red Lid
324.21
Each
C1008-A2-6 0.2mL N/A Adapter
24.08
Each
C1008-A2-8 0.2mL N/A Adapter
30.24
Each
C1008-A5-6 0.5mL N/A Adapter
24.08
Each
C1008-A5-8 0.5mL N/A Adapter
30.24
Each
PR1MA MyFuge Mini
PR1MA 8 Mini Microcentrifuge
Special Order
Quantity: