S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
BrightMax™ White, Light-reflecting, Vinyl Sealing Film
Designed for use with white microplates.
- The light reflective properties on clear-bottom plates maximize the sensitivity of bioluminescence and chemiluminescence assays in bottom-reading luminometers
- Maximizes intensity and signal-to-noise ratios in luminescence assays
- May be used as a backing matrix for microscopy of punch-out samples for filter plates (e.g. ELISPOT assays)
- Features a single split liner for easy application
Applications
- Luminescence
- Fluorescence
- Microscopy
- -40°C to +80°C
TiterSeal™ Sealing Film
- Eliminates the “edge effect” which can occur with plate lids (e.g. greater evaporation in the outside plate wells)
- Provides a secure seal and is easy to remove
- Rigid polyester film features good clarity and easy handling
- Can be used as a temporary economical seal while awaiting further processing
- Features two end-tabs with perforations
- General laboratory use
- Short-term storage
- Incubation
- ELISA
- -40°C to +120°C
SealPlate® ColorTab™ Sealing Film for Sample Identification and Plate Labeling
An inscribed color-coded end-tab can be removed and pasted into a laboratory notebook while the other remains on the plate for identification. The film sheet can be removed from the plate without disturbing the identification label due to the finely perforated end-tabs. Choose from 5 different individual colors or the assortment pack.
- Provides a secure seal and is easy to remove
- Rigid polyester film features good clarity and easy handling
- Features two end-tabs with perforations
Applications
- General laboratory use
- Short-term storage
- Incubation
- ELISA
Temperature Range
- -40°C to +120°C
- Reagents for denaturing and loading RNA samples onto a formaldehyde gel, using MOPS as a buffer
- RNA sample is dissolved in 10µl of DEPC water and mixed with 35µl of denaturing solution. Heat the sample to 65°C for 5 min. Once the solution has cooled, add 5µl of loading dye. The sample is now ready to load into the gel.
- DNase/RNase/Protease free
The RotoCycler Discs are specially made to be used with the Qiagen Rotor-Gene Q Real-Time Rotary Analyzer. Two models are available: a 72-well format with 100 µL tubes and a 100-well format for reactions up to 25 µL. The discs a"one-piece "plate" equivalent, having vertically oriented wells compatible with automated reaction setup using a robotic liquid handling system.
- Used for agarose electrophoresis of DNA, RNA or nucleic acids
- Contains 3 tracking dyes and 15% Ficoll in a special Tris dye
-
- Light blue - around 4000bp in 1% agarose
- Indigo - around 600bp in 1% agarose
- Magenta - around 150bp in 1% agarose
- DNase/RNase/Protease free
Need great dNTPs at a great price? Try PR1MA! Click here to order.
- Mix of dATP, dCTP, dGTP, dTTP
- Each nucleotide is at a concentration of 12.5 mM
- Ready-to-use molecular grade dNTP solution for use in DNA polymerization, DNA labelling and sequencing processes
- High purity: >98% by HPLC
- Supplied in solution at pH 7.5
- dNTPs are stable at -20°C, avoid multiple freeze/thawing (For long-term usage, aliquoting is recommended)
- Functionally tested with thermostable polymerases
- Ready-to-use molecular grade dNTP solution for use in DNA polymerization, DNA labeling and sequencing processes
- High purity: >98% by HPLC
- Supplied in solution at pH 7.5
- dNTPs are stable at -20°C, avoid multiple freeze/thawing (For long-term usage, aliquoting is recommended)
- Functionally tested with thermostable polymerases
- Mix of dATP, dCTP, dGTP, dTTP
- Each nucleotide is at a concentration of 100 mM
- Ready-to-use molecular grade dNTP solution for use in DNA polymerization, DNA labelling and sequencing processes
- High purity: >98% by HPLC
- Supplied in solution at pH 7.5
- dNTPs are stable at -20°C, avoid multiple freeze/thawing (For long-term usage, aliquoting is recommended)
- Functionally tested with thermostable polymerases
dNTP SET
(dATP, dCTP, dGTP, dTTP)
100 mM
Cat. No. |
Size |
dNTP sets each 100mM Solutions |
BE511109 |
20x 4x 250 µL |
dATP, dCTP, dGTP, dTTP |
BE511120 |
4x 2 mL |
dATP, dCTP, dGTP, dTTP |
Store at 20°C For in-vitro laboratory use only
Components Volume dATP (100mM) 250 µL dCTP (100mM) 250 µL dGTP (100mM) 250 µL dTTP (100mM) 250 µL General Description Ready-to-use molecular grade dNTP solution for use in DNA polymerization, DNA labelling and sequencing processes. Features High purity: >98% by HPLC. Supplied in solution at pH 7.5. Storage Conditions dNTPs are stable at 20oC in a constant temperature freezer. Avoid multiple freeze/thawing. For long-term usage, aliquoting is recommended. Quality control Functionally tested with thermostable polymerases. |
Need great dNTPs at a great price? Try PR1MA! Click here to order.
- Mix of dATP, dCTP, dGTP, dTTP
- Each nucleotide is at a concentration of 10 mM
- Ready-to-use molecular grade dNTP solution for use in DNA polymerization, DNA labelling and sequencing processes
- High purity: >98% by HPLC
- Supplied in solution at pH 7.5
- dNTPs are stable at -20°C, avoid multiple freeze/thawing (For long-term usage, aliquoting is recommended)
- Functionally tested with thermostable polymerases
Please know that the manufacturer has suspended manufacturing this product indefinitely.
We suggest purchasing PR1MA PCR Plastics.
Contact your rep or email tech@midsci.com for more information.
Sealing Mat for 96-Well PCR Plates
Reusable and versatile, Axygen AxyMats minimize evaporation in a wide range of temperatures in PCR and storage applications.
eXTReme™ FoilSeal™
eXTReme FoilSeal is an aluminum foil seal that offers excellent chemical resistance and superior performance in ultra-low temperatures.
Application: Long-term storage, light sensitive assays and robotics
- Certified DNase- & RNase- free
- Recommended for -80°C long-term storage
- Excellent chemical resistance (e.g. DMSO)
- Specially formulated adhesive provides an excellent seal to minimize evaporation and well-to-well contamination
- 1.9mil thick aluminum foil removes easily without tearing and allows for visual verification of the seal’s security around each well
- Pierceable with a pipet tip for direct sample recovery
- Not recommended for PCR
- Remove diagonally from a corner to prevent tearing
- Selection of the proper film size will minimize evaporation
- More complete coverage of the plate will reduce evaporation in the outer wells