|◀ 277 - 288 of 399 ▶|
View:

New electronic ballast and cutting-edge construction offers:

  • Increased ultraviolet output and intensity
  • No light flicker
  • Wider intensity range with variable selection (select models)
  • Fast lamp start up
  • Universal power supply
  • Reduced electrical consumption
  • Longer tube life
  • Lighter weight
  • Improved gel visualization and gel documentation
  • High performance 25-watt UV tubes for high fluorescence and sensitivity on stained gels
  • Stainless steel cover frame provide an easy clean surface and reduces cross contamination of samples
  • Uniform, brilliant back-lit fluorescence illumination is enhanced with UVP's unique background uniformity screen and UVG long-life filter
  • Uniformity screen is available on units with midrange or longwave UV
  • The transilluminator's powerful cooling fan maintains a low filter surface temperature to prevent sample damage and maintains a constant UV intensity
  • The removable and adjustable protective UV blocking cover is included with each transilluminator
  • Transilluminators carry a two-year warranty
  • 2 year warranty

WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.

Intensity:
  • Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information. 
  • Variable intensity settings - High/Medium/Low 
  • High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.

UV Source: 254nm, 302nm or 365nm

Watts: 25 watts

Dimensions: All Benchtop models : 13.25D x 19.13W x 5.63H in. 

  • Height includes UV blocking cover
  • Weight: 21 lb. (9.6 kg)

Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.

Part Numbers
100-115V 230V Model Intensity Style Wavelength Filter Size
Variable UV Intensity
95-0420-01 95-0420-02 TFL-40V Variable 365nm 20x40cm
95-0423-01 95-0423-02 TFM-20V Variable 302nm 20x20cm
95-0422-01 95-0422-02 TFM-26V Variable 302nm 21x26cm
95-0424-01 95-0424-02 TFM-30V Variable 302nm 25x30cm
95-0421-01 95-0421-02 TFM-40V Variable 302nm 20x40cm
95-0427-01 95-0427-02 TFS-20V Variable 254nm 20x20cm
95-0428-01 95-0428-02 TFS-26V Variable 254nm 21x26cm
95-0429-01 95-0429-02 TFS-30V Variable 254nm 25x30cm
95-0430-01 95-0430-02 TFS-40V Variable 254nm 20x40cm
2UV
95-0431-01 95-0431-02 TFML-20 Single 302/365nm 20x20cm
95-0432-01 95-0431-02 TFML-30 Single 302/365nm 25x30cm
95-0425-01 95-0425-02 TFML-26 Single 302/365nm 21x26cm
95-0426-01 95-0426-02 TFML-40 Single 302/365nm 20x40cm
Replacement Tubes
Replacement Tube 34-0073-01 25-watt, 254nm
Replacement Tube 34-0072-01 25-watt, 302nm
Replacement Tube 34-0060-01 25-watt, 365nm
Item#:
ASPCRUVEQ6
  • Small footprint for benchtop use
  • Preset and manual controls for ultraviolet or time exposures. Preset exposure delivers 120,000 microjoules or five minutes of exposure
  • Microprocessor measures and control UV output, ensuring maximum energy efficiency
  • Large LED display and touch panel which displays time or energy settings
  • Window on the door allows viewing of the process yet blocks out the UV radiation
  • Select from models with 302nm midrange UV, 365nm longwave UV or 254nm shortwave UV Interior: 12 deep x 10 wide x 5 high inches (305 x 254 x 127mm)
  • Overhead UV supplies uniform UV
  • Shortwave UV model is available with choice of door (CL-1000) or drawer (CX-2000) styles
  • Built-in UV sensor is calibrated at the UVP factory to ensure accuracy and reliability
  • Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking

CL-1000 Dimensions: Exterior: 13.7 deep x 15.6 wide x 8.75 high inches (248 x 396 x 222mm)

CX-2000 Dimensions:
Exterior: 17.5"W x 15"D x 9.75"H (445 x 381 x 248mm)
Interior: 11.4"W x 11.3"D x 3.6"H (290 x 287 x 91mm)
Depth of sample tray 11.25 Width of sample tray 11.5
Sample surface to lamp approximately 3.5 in. (89mm)

1 year warranty

 

Model

Part No. 115V

Wavelength

Replacement Tubes

CL-1000

95-0174-01

254nm

34-0007-01

CL-1000L

95-0228-01

365nm

34-0006-01

CL-1000M

95-0230-01

302nm

34-0042-01

CX-2000

95-0339-01

254nm

34-0007-01

Item#:
ASPCRUVEQ3

Cutting-edge construction of UVP transilluminators includes an electronic ballast for increased stability and reduced power consumption. They also have a compact size to fit conveniently in small laboratory spaces. Benchtop UV transilluminators feature a fast lamp start-up with no light flicker. The FirstLight UV Illuminators offer high sensitivity and <5% coefficient of variance (CV) across the full filter area for consistency across the entire illuminated surface.

Applications:

The FirstLight® UV Illuminator represents a unique highly uniform excitation source for quantitative fluorescent imaging in a wide range of genomic and proteomic applications:

  • Electrophoretic separation and quantiation of 1D and 2D protein separations
  • Solid phase immunoassay
  • DNA quantitation
  • RNA quantitation

Specifications:

 

UV Source:

UV Grid

Wavelength:

302 nm

Intensity:

Single

UV Blocking Cover:

Included

Dimensions (WxDxH):

14x11x5.63 inches

Warranty:

2 year

Item#:
ASPCRUVEQ4
  • Lamps are lightweight.
  • Models available include shortwave, longwave UV or a combination shortwave/longwave version
  • Combination version comes with a snap-on wavelength selector for switching between wavelengths
  • Use these lamps with the J-129 Lamp Stand (pictured) or the C-10 Cabinet
  • 1 year warranty

    Handheld Lamp Dimensions: 
    14.9"L x 3.2"W x 2.5"H
    Lamp Stand Dimensions: 9.5"H x 13"L
Item#:
ASPCRUVEQ1

Shortwave XX Series Lamps use ultraviolet radiation as a reliable and effective tool for sterilization and sanitation applications in hospitals, laboratories, pharmaceutical companies, and clinics. Work surfaces and equipment can become contaminated with bacteria which may be passed through the air or by hand infecting research projects and workers. In addition to bacteria, yeast, mold spores, germs, and viruses may also be present. Shortwave XX Series UV Lamps can kill up to 99% of these organisms. Decontaminate work surfaces with UV prior to PCR to reduce air-borne contamination during DNA sequencing. UV sterilization is particularly useful for temperature sensitive applications due to low operating lamp temperatures. 

Shortwave Lamps can be used in an upward facing position for purifying the air or in a downward position for sanitizing work surfaces. Hanging the lamp (brackets provided) reduces the space required on laboratory benchtops. Longwave UV Bulbs (365nm) also available for all models. 1 year warranty

Dimensions
XX-15:
 19.75"L x 6"W x 4.25"H
XX-20: 24"L x 6"W x 4.25"H
XX-40: 49.6"L x 6"W x 4.25"H
Exposure Stand: 20"L x 6"W x 13"H

Item#:
ASPCRUVEQ2

UltraSlim® LED Illuminator

  • Safer to use that standard UV transillumiators
    • NO UV hazard to skin and eyes.
    • NO DNA damage inherent to UV - No worries when cutting out bands for elution.
  • Easy for use and gel cutting
    • NO need to wear amber glasses.
  • The THINNEST blue LED illuminator in the world.
    • Strong blue LED for excitation.
    • Uniform: <10% coefficient of variance (CV) in the central viewing area.
    • Compact and Light: 30 mm in height
  • Wide applications other than DNA/RNA gel visualization, such as fluorescent proteins.
    • Sensitive for a wide range of fluorphores: DNA SafeStain, GelGreen, GelRed, EthBr, SYBR® Safe, SYBR Gold, SYBR Green I® & II, SYPRO® Rudy, SYPRO® Orange, Coomassie Fluor Orange stains, and Lumitein Protein Gel Stain.

The UltraSlim® LED Illuminator is designed for viewing stained gels on the laboratory bench, or within gel documentation systems. Safer lighting from the LED source inside the instrument produces blue light with a narrow emission peak centered at approximately 470 nm, which is more effective for the excitation of most nucleic acid and protein stains. Viewing surface is 120mm x 70mm.

 

Item#:
SLB-01
Your Price:
1001.00
Each
ladder, 10-180 kDa, 2x250ul

Bullseye Pre-stained Protein Ladder, 10-180 kDa

  • Ready to use - no boiling necessary
  • Stable at ambient temperature
  • 2 reference bands - red at ~75kDa and green at ~25kDa
  • Use 5-15µl, depending on the size of the wells
  • No freeze-thaw involved
  • Broad range ladder

Application: The Bullseye Pre-stained Protein Ladder is suitable for visualizing proteins during electrophoresis without staining and for monitoring transfer onto membrane.

The Bullseye Pre-stained Protein Ladder contains 10 prestained proteins, covering a wide range of molecular weights from 10 to 180kDa. It is designed for monitoring protein separated during polyacrylamide gel electrophoresis, verification of Western transfer efficiency on membranes and for sizing of proteins. The ladder is supplied in protein gel loading buffer and is ready-to-use. No need to heat, dilute, or add reducing agent before loading. One prominent feature of this protein ladder, is that it remains in the liquid state at the storage temperature; therefore, there is not a freeze-thaw cycle involved, making the ladder very stable.


Contents:
0.1~0.4 mg/ml of each protein in 20 mM Trisphosphate (pH 7.5 at 25°C), 2% SDS, 1 mM reducing reagent, 3.6 M Urea, and stabilizer.

Usage:
For each application, 5-15µl is needed, depending on the size of the wells.

Quality Control:
Tested in polyacrylamide gel electrophoresis and Western Blotting.

Storage: -20 °C.

Note for image:

The apparent molecular weight of each protein (kDa) has been determined by calibration against an unstained protein ladder in each electrophoresis condition.
Item#:
BEPAR
Your Price:
107.69
Each

Autoradiography Cassette Aluminum 5x7

Classic Push-Button Cassettes

  • Constructed From Lightweight Aluminum & Nylon
  • Special Curved Door Gives Exceptional Screen-Film Contact
Item#:
ASCASSETTES

RunBlue gels are more rigid and up to 10 times stronger than conventional precast gels resulting in more robust gels that can be handled with confidence. No tearing - an 8% gel can be thrown into the air and caught without breaking!

  • RunBlue gels are manufactured using a unique method of polymerisation that results in more uniform and more complete polymerisation of the Acrylamide when compared to conventional, chemical based methods. This results in gels that have superior batch to batch reproducibility and practically eliminates exposure to un-polymerised Acrylamide.
  • RunBlue gels incorporate a stacking gel that has been dyed (red for SDS) for the simplest ever sample loading. In addition, there is no comb to remove as the top of the teeth are fixed in place. This not only prevents the teeth from being accidentally torn off during comb removal but that all of the wells are uniform, with the teeth remaining vertical. This prevents sample cross contamination / inability to load desired Vol. The teeth also protrude above the lower front plate of the gel cassette preventing sample flow over into adjacent wells.
  • Runblue gels are available in two different cassette sizes providing compatibility with the most common gel tanks and apparatus.  10x10 cm cassettes are compatible with Invitrogen/Life Technologies equipment and any other equipment designed for this format, such as the Hoeffer and Owl tanks. Our 8x10 cm cassette is designed to fit the Biorad equipment (Mini Protean I, II and II, Tetra etc).
  • The resolving gel on RunBlue gels extends to the very bottom of the cassette which not only provides improved resolution but also there is no protruding gel that requires trimming prior to blotting. There is also no additional tape / covers to remove - simply take the gel from the pack and use.
  • RunBlue gels are supplied in boxes of 10 gels. They are available in a 12 well format, covering a range of concentrations and gradients.

Benefits of RunBlue Precast Gels

  • 2 year shelf life - never throw away another gel
  • Up to 10x stronger - no more torn, ruined gels
  • Load up to 20µl - see everything in your sample
  • Dyed stacking gel - makes gel loading child's play (SDS = Red)
  • No comb to remove - no more broken or bent teeth
  • Full length resolving gel - improved resolution and better blotting
  • 10x10 cm and 8x10 cm cassette - total compatibility with most popular tanks including Invitrogen and Biorad equipment
  • Fast delivery with immediate and expert technical support for total peace of mind
  • Best value gels available - save money!
Item#:
ASPRECASTGBIOR

MAXI Flex Tube Kit

MAXI Flex Tubes combine two modes of action: electro-elution of nucleic acid molecules from polyacrylamide or agarose gels and dialysis or buffer exchange of protein molecules. Flex Tubes allow rapid, secure, simple loading and recovery, with high performance as the most convenient, user friendly, electro-elution and dialysis system on the market.

KIT CONTENTS

  • Flex Tubes 2/10/30/50/ 100 pieces
  • Supporting tray (for electro elution protocol) 1ea. (select kits)
  • Floating rack (for dialysis protocol) 1ea. (select kits)
  • Information and Protocol Manual 1ea.

SPECIFICATIONS

  • Membrane cut-off: 3.5K(11bp), 6-8K(18-24bp), 12-14K(36-42bp), 25K(76bp) or 50K(152bp) MWCO
  • Tube volume: 3ml
  • Dialysis volume: 0.1-3ml
  • Min. sample size for extraction: 20µg
  • Max. gel slice: 2cm x 1cm
  • Membrane ultra-clean, sulfur and heavy metal free. EDTA treated
  • Flex Tube MWCO are in kilo Daltons (K) for proteins and corresponding base pairs (bp) for nucleic acids as indicated in the table below:

kilo Daltons

base pairs

1K

3 bp

3.5K

11bp

6-8K

18-24bp

12-14K

36-42bp

25K

76bp

50K

152bp

 

APPLICATIONS

  • Dialysis, electro-elution or buffer exchange with volumes between 0.1-3ml
  • Preparation of protein samples for MALDI-MS
  • Sample concentration
  • Large-scale protein dialysis, such as antibodies and recombinant protein purification
  • Removal of contaminating micro-molecules
  • Tissue culture extraction purification
  • Removal of salts, surfactants, solvents, and detergents
  • Complex formation studies (protein-protein, protein-DNA, and protein-RNA)
  • pH and buffer adjustment of sample solutions, protein extraction or cell extraction
  • High throughput dialysis
  • Peptide dialysis, as small as 10 amino acids
  • Virus-particles purification
Item#:
ASISOLAION2

MIDI Flex Tube Kit

MIDI Flex Tubes combine two modes of action: electro-elution of nucleic acid molecules from polyacrylamide or agarose gels and dialysis or buffer exchange of protein molecules. Flex Tubes allow rapid, secure, simple loading and recovery, with high performance as the most convenient, user friendly, electro-elution and dialysis system on the market.

KIT CONTENTS

  • Flex Tubes 2/10/30/50/ 100 pieces
  • Supporting tray (for electro elution protocol) 1ea. (select kits)
  • Floating rack (for dialysis protocol) 1ea. (select kits)
  • Information and Protocol Manual 1ea.

SPECIFICATIONS

  • Membrane cut-off: 1K(3bp), 3.5K(11bp) or 6-8K(18-24bp) MWCO
  • Tube volume: 800µl
  • Dialysis volume: 50-800µl
  • Min. sample size for extraction: 0.5µg
  • Max. gel slice: 1cm x 0.5cm
  • Membrane ultra-clean, sulfur and heavy metal free. EDTA treated
  • Flex Tube MWCO are in kilo Daltons (K) for proteins and corresponding base pairs (bp) for nucleic acids as indicated in the table below:

kilo Daltons

base pairs

1K

3 bp

3.5K

11bp

6-8K

18-24bp

12-14K

36-42bp

25K

76bp

50K

152bp

 

APPLICATIONS

  • Dialysis, electro-elution or buffer exchange with volumes between 50-800µl
  • Preparation of protein samples for MALDI-MS
  • Sample concentration
  • Large-scale protein dialysis, such as antibodies and recombinant protein purification
  • Removal of contaminating micro-molecules
  • Tissue culture extraction purification
  • Removal of salts, surfactants, solvents, and detergents
  • Complex formation studies (protein-protein, protein-DNA, and protein-RNA)
  • pH and buffer adjustment of sample solutions, protein extraction or cell extraction
  • High throughput dialysis
  • Peptide dialysis, as small as 10 amino acids
  • Virus-particles purification.
Item#:
ASISOLAION4

MEGA Flex Tube Kit

MEGA Flex Tubes enable user friendly dialysis or buffer exchange of protein molecules with rapid, secure and simple loading along with high performance yield recovery.

KIT CONTENTS

  • Flex Tubes 2/10/30/50/ 100 pieces
  • Floating rack (for dialysis protocol) 1ea. (select kits)
  • Information and Protocol Manual 1ea.

SPECIFICATIONS

  • Membrane cut-off: 1K, 3.5K, 6-8K or 12-14K MWCO
  • Tube volume: 10ml, 15ml or 20ml
  • Dialysis volume: 3-20ml
  • Membrane ultra-clean, sulfur and heavy metal free. EDTA treated
  • Flex Tube MWCO are in kilo Daltons (K) for proteins

APPLICATIONS

  • Dialysis or buffer exchange with volumes between 3-20ml
  • Preparation of protein samples for MALDI-MS
  • Sample concentration
  • Large-scale protein dialysis, such as antibodies and recombinant protein purification
  • Removal of contaminating micro-molecules
  • Tissue culture extraction purification
  • Removal of salts, surfactants, solvents, and detergents
  • Complex formation studies (protein-protein, protein-DNA, and protein-RNA)
  • pH and buffer adjustment of sample solutions, protein extraction or cell extraction
  • High throughput dialysis
  • Peptide dialysis, as small as 10 amino acids
  • Virus-particles purification
Item#:
ASISOLAION3
|◀ 277 - 288 of 399 ▶|
View: