S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
PCR/qPCR
MIDSCI can supply almost every needed product for PCR/qPCR: tubes, plates, strips, caps, taq, Mastermixes, dNPTs, dye and probe for qPCR, sealing film and much more. If you are looking for any of these things, we can match almost all needs to all cyclers. If you don’t find it easily contact us at tech@midsci.com and we will find it for you.
96 or 384 we have it. Non-Skirted, semi-skirted or full skirted, we have it. 0.1, 0.2, or 0.5 mL we have it. A1, A12, H12, A24, P24 cuts, we have them. Sybr© Green or probe alternative, we have it.
Pro Tip: Colored plastics do not have any impact on DNA amplification. But when setting up qPCR it is often recommended to use white plastics. This will limit or prevent fluorescence refraction. Light refraction can minimize sensitivity and consistency.
Pro Tip 2: If you are seeing inconsistencies in PCR/qPCR try PR1MA Pipette Tips. This will help optimize and reduce variance in the reactions. Simple test, see the residual liquid left in tips? This means some of the taq, dNTPs, sample, etc is left in the tip. PR1MA tips help reduce that significantly and improve your consistency.
Pro Tip 3: Seeing evaporation in the outer wells of a PCR/qPCR plate? Sometimes it’s the plate, sometimes it the seal, and sometimes it’s the cycler. Call us we have solutions.
MultiGene™ Thermal Cycler
MIDSCI bring you the new MultiGene™ Thermal Cycler, which guarantees to produce consistent and reliable results while making gradient technology affordable. This unit is extremely simple to program, compact in design and built to perform.
Features:
- Faster speeds - up to 30 min
- Gradient capability
- 6-segment block temperature control
- Independent block temperature selection capabilities
- Precision thermal control
- TM calculator
- PC Viewer
- No condensation after overnight cooling at 4°C
- Simple, user-friendly programming
- 3-yr warranty
The MultiGene™ OptiMax employs a new protocol optimization process improving on older gradient features. The OptiMax utilizes Flex™ technology that effectively separates the 96 well plate into 6 - (4 x 4) temperature regions that allow you to pick the temperatures you want to test against. These regions are easily identified by the blue and black squares visible on the microplate platen. Instead of having the thermal cycler choose temperatures for you, you can choose any temperatures you want within a 24°C range.
The MultiGene™ OptiMax has a heating rate of 4°C /sec and a cooling rate of 3°C/sec. We have minimized overshooting and undershooting so that your reactions only see the temperatures they are supposed to see. This also leads to faster runs time.
New is the PC Viewer Option.
By downloading our software from our website and attaching a USB cable to your Windows PC to can view the temperature profiles real time as they are occurring to monitor your system.
Intuitive User Interface
The MultiGene™ OptiMax utilizes an intuitive user interface. This user interface is friendly to the laboratory environment and consistent with what our customers previously enjoyed in our earlier models. It can be used with lab gloves even if wet. We have improved the ramping speed and eliminated overshooting and undershooting which contributes to longer run times.
Fully Adjustable Heated Lid
The OptiMax's heated lid is fully adjustable to provide optimum pressure for use with a broad range of tubes and microplates. For optimum performance, the lid can also be programmed to hold different temperatures between 60° to 65°C and 100° to 115°C. The OptiMax lid prevents condensation and slides away and back from the user to provide full access to samples and reduce the risk of coming in contact with a hot surface.
Product Specifications:
Sample Capacity |
1 x 96 well plate, 12 8 x 0.2 mL strip tubes, 96 x 0.2 mL tubes |
Programmable Temperature Range |
4°C to 99.9°C |
Temperature Control |
Calculated or block |
Temperature Accuracy/Uniformity |
±0.5°C/±0.5°C |
Heating/cooling method |
Peltier |
Max. heating/cooling rate |
4°C/3°C per second |
Temperature range of 6-segment blocks |
30°C to 99°C. Temperature of 6-segment blocks can be set independently. |
Maximum Temperature difference between 6-segment blocks |
24°C |
6-segement temperature blocks |
6 temperature blocks in 4 x 4 well format |
Programmable lid temperature |
60° to 65°C, 100° to 115°C |
Program memory |
200 complete programs |
Temp. increments/decrements |
Yes |
User program folders |
50 sets |
Password protected programs |
Yes |
Communication |
USB and RS232 ports |
Dimensions (W x D x H) |
9.4 x 16.5 x 9.8 inches |
Weight |
19.8 lbs |
Electrical |
120 V (TC9610) or 240 V (TC9610-230), 50/60 Hz |
PR1MA™ Corbett Type PCR Tubes
- PR1MA™ PCR Strip Tubes and Caps are evaporation-resistant and provide easy-to-open-and-close lids that prevent sample loss.
- Tube Size is 0.1 mL
- 4 Tube Strip and 4 Cap Strip
- The uniform wells and ultra-thin walls provide optimal heat transfer and reaction efficiency.
- Reclosable bags minimize contamination risk and are convenient for opening and closing.
- For use in medical, pharmaceutical, food industry, and molecular biology.
- Certified free of detectable RNase, DNase, NA, PCR inhibitors, and tested pyrogen-free.
- 96-well, 8 x 12 format
- Holds 0.2ml PCR tubes, strip tubes, and plates (does not fit full skirted plates)
- Supplied with clear lift-off lids
PR1MA™ SmartGlow™ DNA Safe Stain
- Replaces hazardous Ethidium Bromide (EtBr)
- Better sensitivity than EtBr
- Detect as little as 0.1ng of DNA
- Two types available
- PS Pre Stain
- LD Loading Dye
- Excitation by UV light or blue light
- Compatible with Accuris SmartBlue™ Transilluminator
- Ships at ambient temperature (stored at 4°C)
PR1MA™ SmartStain™ PS (Pre-Stain) can be used as a direct replacement for Ethidium Bromide in agarose and polyacrylamide gel electrophoresis. The stain emits green fluorescence when bound to dsDNA or ssDNA and emits red fluorescence when bound to RNA. PR1MA™ SmartStain™ PS exhibits excitation peaks at 290 nm and 490 nm, allowing it to be used with UV and blue light.
Protocol:
- Prepare 100 mL of agarose or polyacrylamide solution.
- Add 5 µL of PR1MA™ SmartStain™ to the gel solution before pouring gels.
- For enhanced results, add PR1MA™ SmartStain™ PS to the running buffer at a ratio of 5 µL per 100 mL. Adding PR1MA™ SmartStain™ PS to the running buffer will result in increased sensitivity and better detection of small quantities of nucleic acid.
- After electrophoresis is complete, view the gel using a UV or blue light illuminator
IsoFreeze PCR and IsoFreeze PCR SBS are innovative, high performance, personal chiller racks. Using proven IsoFreeze temperature maintenance technology, the filled racks maintain a cool(refrigerator) environment on the bench or on the workstation platform. IsoFreeze gives a chilled and stable environment for PCR reagents, cells, enzymes or other temperature sensitive reagents.
Industry Standard format tubes, strips and 96 well plates, in both standard and low profile well shape, are accommodated and are efficiently cooled in PCR, QPCR and many other applications.
IsoFreeze PCR Racks are manufactured using polypropylene containing novel, temperature dependent color-change dye giving simple, at-a-glance, temperature indication for each well. There is a dramatic change to a contrasting color at 7C. IsoFreeze gel technology means the wells will stay cool for up to 4 hours (see charts below), depending on ambient temperature and other factors.
IsoFreeze PCR can keep your sample cool for over 4 hours!
IsoFreeze PCR SBS high performance is ideal for your automated systems!
IsoFreeze PCR and IsoFreeze PCR SBS available in 2 color change formats!
- Superior sensitivity and fast cycling with exceptional results
- Ideal for low copy number templates
- Early Ct values and detection across a broad dynamic range
- Ready to use 2X Master Mix
- Includes PR1MA Hot Start Taq Polymerase for greater specificity and accuracy
Supplied as a ready-to-use 2X master mix, PR1MA qMax Green has been engineered for high sensitivity, fact cycling and excellent reproducibility. PR1MA Hot Start Polymerase provides accurate PCR of a variety of templates including low copy number and difficult sequences, while the proprietary qMax Green intercalating dye exhibits higher fluorescence and lower PCR inhibition than other popular green dyes.
These two components are supported by a specially formulated buffer with an exacting combination of salts, PCR enhancers, stabilizers and pH that results in earlier Ct values and a high specificity across a broad dynamic range.
*Please note these
products ship on dry ice. Appropriate shipping charges apply unless
otherwise noted on a quote.
PR1MA Taq Plus
- Higher fidelity for long PCR amplicons, up to 35 kb
- Ideal for problematic templates
- Better sensitivity and higher activity for low copy and long PCR
- Enzyme of choice for TA cloning
PR1MA Taq Plus, an optimized blend of our Hot Start Taq and a proofreading polymerase, provides 5X better fidelity than wild-type Taq and increased enzyme activity. It is the perfect choice for GC and AT rich templates, low copy number and long PCR.
The 3' -5' exonuclease activity of the proofreading enzyme produces fragments suitable for TA cloning. PR1MA Taq Plus is provided with a 5X buffer with dNTPs or in a convenient one tube 2X Master Mix.
PR1MA Taq Start Taq DNA Polymerase
Item |
Description |
Volume |
PR1000-TP-S |
PR1MA Taq Start Taq
DNA Polymerase |
50 Units (Sample) |
PR1000-TP-250 |
PR1MA Taq Start Taq
DNA Polymerase |
250 Units (5 U/p1) |
PR1000-TP-500 |
PR1MA Taq Start Taq DNA
Polymerase |
1,000 Units (5 U/p1) |
PR1MA Taq Plus Master Mix, 2X Concentration
Item |
Description |
Volume |
PR1001-TP-S |
PR1MA Taq Plus Master
Mix, 2X Concentration |
20 Reactions (Sample) |
PR1001-TP-200 |
PR1MA Taq Plus Master
Mix, 2X Concentration |
200 x 50 µL Reactions |
PR1001-TP-1000 |
PR1MA Taq Plus Master
Mix, 2X Concentration |
1,000 x 50 µL Reactions |
The Azure Cielo Real-Time PCR system provide accuracy and sensitivity needed for research, with intuitive touch screen software.
Product Features- Flexibility: Engineered for a wide variety of qPCR applications, with high sensitivity and wide dynamic range.
- Intelligent workflow: The user interface is a simple touch screen assay setup. Protocols can be saved to make assay set up easy and reproducible.
- Reliability: Cielo's optics and thermal block are designed to deliver the same uniformity and reproducibility over at least 1,000 qPCR experiments, giving you confidence in the reliability of the instrument.
- Connectivity: An external PC is not required to run the instrument.
- Data Transfer: This can be performed via Ethernet, Wi-Fi or USB.
Operation - A standalone qPCR system with
10.3” touchscreen interface
Optics - 3 or 6 dye channel filters with LED based
excitation for multiplexing
Speed - Fiber optic detection system scans 16 wells simultaneously
Durability - Tested
reliability for over 1000 continuous runs
Connectivity - Easily
export data via Wi-Fi, ethernet, USB or LAN
Capacity - 96-well format for semi-skirted or un-skirted plates and
tubes
Thermal Performance - Marlow
Peltier based block with 12 temperature gradient zones, ramp rates up to
6.0°C/sec
Chemistry - Supports
reaction volumes between 10 μl–150 μl, open source chemistry, including FAST
~20 minute run-times
Sensitivity - Detect
2-fold differences in target quantities in singleplex reactions and up to 1
copy of amplified DNA, 10 logs of dynamic range
Azure
Cielo 3 AIQ030 |
Azure
Cielo 6 AIQ060 |
|
Dyes/Probes |
||
SYBR™ Green, EvaGreen™, FAM™ |
x |
x |
VIC®, HEX™, JOE™, CAL Fluor® 540, CAL Fluor® Orange 560 |
x |
x |
TAMRA™ |
|
x |
ROX™, TEX®615, CAL Fluor® Red 610 |
|
x |
Cy®5, Quasar®670, Liz®, Mustang Purple® |
x |
x |
Cy®5.5 |
|
x |
Other
dyes/probes are possible depending on the system configuration. |
- Same high efficiency for multiplex and singleplex reactions
- Includes PR1MA Hot Start Taq Polymerase for greater specificity and accuracy
- Compatible with popular hydrolysis and beacon probes
- Ready to use 2X mastermix
- Early Ct values and detection across a broad dynamic range
Optimized for use with TaqMan™, Scorpions® and molecular beacon probes, qMax Probe qPCR Mix is a ready-to-use formulation for real time quantitative assays. qMax Probe utilizes PR1MA Hot Start Taq Polymerase or robust PCR with a variety of templates. A specially formulated buffer provides optimal conditions for both superior polymerase function and probe detection, resulting in earlier Ct values and a broad detection range. Complicated, multiplex reactions can be performed without any loss in performance or decrease in detection. The 2X mix requires little, if any optimization and can be used with both fast and standard protocols.
PR1MA qMax Probe qPCR Mix can be used to detect any DNA template, including genomic DNA and cDNA. Available in high, low and no ROX formulations, qMax Probe is compatible with most qPCR instruments.
*Please note these products ship on dry ice. Appropriate shipping charges apply unless otherwise noted on a quote.
- Designed for convenience & versatility, this rack can be used while you are working or as a storage rack.
- It includes a lid and can accomodate 32 x 0.2 ml PCR tubes, 24 x 1.5/2.0 ml & 16 x 0.5 ml microtubes.
- Tube wells are alpha-numerically matrixed with raised bold type for quick identification.
- If you use cycle plates, 8 or 12 tube strips, or lage quantities of 0.2 ml PCR tubes, the WRI-4A is for you.
- Four retainer clips hold the tray firmly in place, yet allow fast and convenient removal when necessary.
- Available with a clear lid and five flourescent colors: blue, green, orange, pink, yellow, or assorted.
MyGo Mini S
- Small format 16 x 0.1 mL QPCR System with Taqman Multiplexing at an amazing price.
- Amazing accuracy and easy to use software that allows you to control 100s of systems with one PC and analyze the data at the same time. Windows, Linux and Mac OSX
- Solid state reliability with up to 5-year warranty
Precision and Performance
The MyGo Mini demonstrates superior intra-run and inter-run analytical precision in DNA quantification and melting point analysis. Users can now address biological phenomena with subtle effects on gene expression, or pathogen levels, for example discriminating 10% differences in transcript concentrations. For users performing HRM-based analysis of genetic variants, the combination of thermal control, optical data quality and HRM data analysis of the MyGo Mini S system provide compelling functionality. The system can discriminate all classes of SNP, including Class 4 SNPs via HRM.
Users can now address biological phenomena with subtle effects on gene expression, or pathogen levels, for example discriminating 10% differences in transcript concentrations.
For users performing HRM-based. analysis of genetic variants, the combination of thermal control, optical data quality and HRM data analysis of the MyGo Mini system provide compelling functionality. The system can discriminate all classes of SNP, including Class 4 SNPs via HRM.
Easy Analysis
The MyGo Mini system comes with easy-to-use software, and robust, high performance algorithms which provide accurate results from complex data. Automated analysis of complex HRM data makes this powerful technique more accessible to non-experts, and minimizes operator-dependent variability in data analysis. Automated report generation makes life easier for service providers, and users operating within GLP quality systems.
Automated report generation makes life easier for service providers, and users operating within GLP quality systems.
Specifications
Number of Reactions |
16 |
Format |
0.1 mL tubes |
Reaction Volume |
10-100 µl |
Temperature Control Method |
Peltier |
Speed |
3°C/s heating | 1.5°C/s cooling |
Temperature Uniformity |
0.05°C (SD) |
Temperature Accuracy |
± 0.25°C |
Temperature Resolution |
0.01°C |
Connection Options |
LAN - up to 400 instruments |
Direct connection - RJ45 |
|
Stand alone - USB stick |
|
Detection |
500 to 650 nm (CMOS array) |
Multiplex Level |
Duplex |
Sensitivity |
Single copy detection |
Dynamic Range |
9-log |
Precision |
1.1 fold discrimination |
Factory Calibrated Dyes |
ATTO 490LS, CAL 540, |
CAL 560, FAM, HEX, |
|
LC Green, ResoLight, ROX, |
|
SYBR Green, SYTO 9, VIC |
|
Choice of Custom Dyes |
Yes |
Supported Assay Formats |
TaqMan |
Intercalators |
|
HRM |
|
Operating Noise |
Silent |
Power |
90W |
Warranty |
Up to 5 years |
MyGo Pro
- Small format 32 x 0.1 mL QPCR System, holds four 8 x 0.1 mL Strips.
- Runs 45 cycles in 33 minutes.
- Amazing accuracy and easy to use software that allows you to control 100s of systems with one PC and Analyze the data at the same time. Windows, Linux and Mac OSX.
- Solid state reliability with option of 5-year warranty.
Precision and Performance
The MyGo MPro demonstrates superior intra-run and inter-run analytical precision in DNA quantification and melting point analysis.
Users can now address biological phenomena with subtle effects on gene expression, or pathogen levels, for example discriminating 10% differences in transcript concentrations.
For users performing HRM-based analysis of genetic variants, the combination of thermal control, optical data quality and HRM data analysis of the MyGo Mini S system provide compelling functionality. The system can discriminate all classes of SNP, including Class 4 SNPs via HRM.
Easy Analysis
The MyGo Pro system comes with easy-to-use software, and robust, high performance algorithms provide accurate results from complex data. Automated analysis of complex HRM data makes this
powerful technique more accessible to non-experts, and minimizes operator-dependent variability in data analysis. Automated report generation makes life easier for service providers, and users operating within GLP quality systems.
Specifications
Dimensions ( w x d x h) | 25 x 27 x 23 cm |
Weight | 7 kg |
Operating noise | <40 db(A) |
Electrical | |
Voltage | 100 - 240V AC ± 10% |
Frequency | 50-60Hz ± 10% |
Power | 170W |
Number of reactions | 32 |
Format | 0.1 mL tubes / 8-tube strips |
Reaction volume | 10 - 100 L |
Temperature control | |
Method | Peltier |
Range | 37-99°C |
Speed | 5°C/s heating, 4°C/s cooling |
Resolution | 0.01°C |
Uniformity | 0.05°C (SD) |
Accuracy | ± 0.25°C |
Run time | < 40 minutes |
Fluorescence | |
Excitation | 500 nm (blue LED) |
Detection | 510 to 750 nm (CMOS array) |
Channels | 120 optical channels |
PCR | |
Sensitivity | Single copy detection |
Dynamic range | 9-log |
Precision | 1.1 fold discrimination |
Factory calibrated dyes | SYBR Green I, ResoLight, FAM, VIC, HEX, Yellow 555, Red 610, TexasRed, Cy5, CAL 540, CAL 560, CAL 590, CAL 610, CAL 635, JOE, Pulsar 650, Quasar 570, Quasar 670, Quasar 705, ROX, TAMRA, TET |
User Chosen Custom Dyes | Yes |
Supported Assay Formats | Intercalating dyes (e.g.) SYBR Green I), Hydrolysis Probes, Molecular Beacons, SimpleProbes, HybProbes |
Connection Options | LAN, Direct connection to computer (RJ45), PC-free (USB stick) |