MIDSCI can supply almost every needed product for PCR/qPCR: tubes, plates, strips, caps, taq, Mastermixes, dNPTs, dye and probe for qPCR, sealing film and much more. If you are looking for any of these things, we can match almost all needs to all cyclers. If you don’t find it easily contact us at tech@midsci.com and we will find it for you.
96 or 384 we have it. Non-Skirted, semi-skirted or full skirted, we have it. 0.1, 0.2, or 0.5 mL we have it. A1, A12, H12, A24, P24 cuts, we have them. Sybr© Green or probe alternative, we have it.
Pro Tip: Colored plastics do not have any impact on DNA amplification. But when setting up qPCR it is often recommended to use white plastics. This will limit or prevent fluorescence refraction. Light refraction can minimize sensitivity and consistency.
Pro Tip 2: If you are seeing inconsistencies in PCR/qPCR try PR1MA Pipette Tips. This will help optimize and reduce variance in the reactions. Simple test, see the residual liquid left in tips? This means some of the taq, dNTPs, sample, etc is left in the tip. PR1MA tips help reduce that significantly and improve your consistency.
Pro Tip 3: Seeing evaporation in the outer wells of a PCR/qPCR plate? Sometimes it’s the plate, sometimes it the seal, and sometimes it’s the cycler. Call us we have solutions.
Click here to Order Now!
- Plate Characteristics
- 96 x 0.1mL, Sub-skirted, cuttable
- Low Profile (0.1mL), Frosted (low signal to noise ratio
- Extreme Uniformity (EU) Plate Design
- Uniform wall thickness ensures consistent even heating
- Thin wall-bottomed tube for rapid heat transfer
- Ideal paring with EU Caps with "Sealing Ring Band" Design
- Easy open - easy close with ergonomic caps: B57801, B79701, C79701
- Caps are significantly easier to apply and remove -- Repetitive Strain Injury (RSI) Friendly.
- Significant reduction in evaporation due to a wider sealing area.
- Certified DNA, DNase, RNA, RNase and pyrogen-free
Please give us a call for a sample!
Order# |
Description |
Non-Skirt |
|
B70501 |
Pryme PCR Plate, 96-Well, 0.2mL, Non-Skirt, Cuttable, Regular Profile, Natural, 25/cs |
B70509 |
Pryme PCR Plate, 96-Well, 0.2mL, Non-Skirt, Cuttable, Regular Profile, White, 25/cs |
B50501 |
Pryme PCR Plate, 96-Well, 0.2mL, Non-Skirt, Cuttable, Regular Profile, Frosted, 25/cs |
AB70651 |
Pryme PCR Plate, 96-Well, 0.1mL, Non-Skirt, Low Profile, Frosted, 25/cs |
Semi-Skirted |
|
B70651 |
Pryme PCR Plate, 96-Well, 0.2mL, Semi-skirted, Cuttable, Regular Profile, Natural, 25/cs |
B70659 |
Pryme PCR Plate, 96-Well, 0.2mL, Semi-skirted, Cuttable, Regular Profile, White, 25/cs |
B50651 |
Pryme PCR Plate, 96-Well, 0.2mL, Semi-skirted, Cuttable, Regular Profile, Frosted, 25/cs |
B17480 |
Pryme PCR Plate, 96-Well, 0.1mL, Semi-skirted, Low Profile, Frosted, 25/cs |
B17489 |
Pryme PCR Plate, 96-Well, 0.1mL, Semi-skirted, Low Profile, White, 25/cs |
Sub-Skirted |
|
ABI7501 |
Pryme PCR Plate, 96-Well, 0.2mL, Sub-skirted, Regular Profile, Frosted, 25/cs |
ABI7509 |
Pryme PCR Plate, 96-Well, 0.2mL, Sub-skirted, Regular Profile, White, 25/cs |
AB19800-EU |
Pryme PCR Plate, 96-Well, 0.1mL, Sub-skirted, Low Profile, Frosted, 25/cs |
AB19809-EU |
Pryme PCR Plate, 96-Well, 0.1mL, Sub-skirted, Low Profile, White, 25/cs |
Caps |
|
B57801 |
Pryme PCR Ergonomic 8-Strip, Optical Flat (V2) Caps, Natural, 120/cs |
B79701 |
Pryme PCR Ergonomic 8-Strip, Optical Flat (V1) Caps, Natural, 120/cs |
C79701 |
Pryme PCR Ergonomic 8-Strip, Semi-Domed (V1) Caps, Natural, 120/cs |
We suggest purchasing PR1MA PCR Plastics.
Contact your rep or email tech@midsci.com for more information.
- Standard thermal cycling and qPCR compatible
- Ultra-thin and consistent wall thickness for precise thermal transfer
- Made from 99.9% virgin polypropylene
- Single notch corner
- 335ul well capacity (working capacity dependent on closure method)
- Fits standard thermal cyclers, ABI Real Time PCR 7300, 7500, 7900, qPCR and ABI Sequencing
- Certified DNAse/RNAse and pyrogen-safe
SealPlate® RollMate™ Pre-scored Film in a Convenient, Easy to Use Roll Format
Pre-scored film on a roll is a more economical and efficient alternative to rapidly seal microplates or racked test tubes; faster than applying single sheeted film. Self-standing, non-slip supports hold the pre-scored film roll securely in place for quick and easy bench-top dispensement. The roll unwind tension can be easily adjusted to user preference. Continuous backing liner can be torn off or fed directly into a waste basket for disposal.
- Economical
- Quicker, more efficient sealing
- Provides a secure seal and is easy to remove
- Rigid polyester film features good clarity and easy handling
- Can be used as a temporary seal while awaiting further processing
- General laboratory use
- Short-term storage
- Incubation
- ELISA
- -40°C to +120°C
- Higher sensitivity
- Use in the same way as EtBr in agarose gel electrophoresis
- Detection of DNA and RNA
- Safest DNA stain by far
- Low cost
- 10,000X
- Excitation wavelengths at 290nm and 490nm
DNA SafeStain Plus is a highly sensitive green fluorescent DNA/RNA staining reagent for detecting nucleic acids in agarose and polyacrylamide gels. This unique stain gives high sensitivity for detection of double-stranded or single-stranded DNA and RNA. Gels can be post-stained or the stain can be added to gels during gel casting or to the gel running buffer. DNA SafeStain Plus has two excitation wavelength peaks at about 290nm and 490nm, and an emission wavelength at 530nm, making it compatible with a standard UV light box, a blue-light transilluminator, or a gel reader equipped with visible light excitation; such as, a 488 nm laser-based gel scanner.
DNA SafeStain Plus is in a 10,000X concentrated format that can be easily diluted 10,000 times for use in precast gel staining, or 5,000 times for use in post gel staining.
Samples stained with DNA SafeStain Plus are compatible with downstream molecular biology applications; such as, gel extraction, and cloning.
- Safest DNA stain by far
- Replaces EthBr in agarose gel electrophoresis
- Detection of DNA and RNA
- Excitation at 290nm & 490 nm
- Emission at 530nm
DNA SafeStain is a new and safe nucleic acid stain for visualization of double-stranded DNA, single-stranded DNA, and RNA in agarose gels. The dyes are developed to replace toxic ethidium bromide (EthBr, a potent mutagen), commonly used in gel electrophoresis for visualization of nucleic acids in agarose gels. DNA SafeStain is non-carcinogenic by the Ames-test. The results are negative in both the mouse marrow chromophilous erthrocyte micronucleus and mouse spermary spermatocyte chromosomal aberration tests.
DNA SafeStain emits green fluorescence when bound to DNA. It has two excitation wavelength peaks when bound to nucleic acid, at 290nm and 490nm and the emission can be detected at 530nm.
Storage:
Store under dark at 4°C or room temperature.
User Instruction:
DNA SafeStain can be used in the exact same way as EtBr in agarose gel electrophoresis. For example, add 100µl to 1 liter of 1X running buffer (1xTAE or 1x TBE), and use this DNA SafeStain containing buffer to make the agarose gel and run the gel.
Special Notes:
1. For best results, dilute the DNA SafeStain 1:10,000 in your gel running buffer and use this dye-containing running buffer to make your agarose gel and to run the gel.
2. As is the case with EtBr; add more DNA SafeStain, if brighter DNA bands are desired. To view the results, any conventional DNA gel viewing light box or gel documentation system should work well with the DNA SafeStain; although, using a LED light instead of a UV light source is preferred due to the harmful nature of UV light.
This Product is For Research Use Only
For the proper disposal of this product, follow University or Company Guidelines.
EZcap™FoilStrips
An economical and more user-friendly alternative to PCR strip caps; no sore thumbs and fingers guaranteed!
- Certified DNase- & RNase- free
- Each sheet contains 6 strips on a continuous liner for ease of use
- Pierceable with a pipet tip or robotic probe for direct sample recovery
- The conformable nature of foil allows for the visual verification of the seal’s security around each well
- 2.0mil aluminum foil removes easily without tearing
- A non-locking workstation is recommended for sample prep (e.g. 96-well round-boom plate)
- Removal of the end-tabs at the perforations is recommended before cycling
- A final sealing step is highly recommended in the thermal cycler because 8-tube strips flex during handling
- Do not fold foil around sides of tubes
- The CleanSpot is designed to fulfill a very important laboratory need...control of PCR contamination.
- Just 25 - 30 minutes of UV irradiation in the CleanSpot can prevent unwanted PCR contamination.
- The combination of a special light reflector and two powerful overhead UV bulbs generate Pyrimidine Dimers (T,C) and other photo defects in contaminating target sequences, thus eliminating falsely primed products that result in countless lost time and expense.
- The CleanSpot is designed to prevent unwanted contaminant DNA in amplification mixtures, thereby saving many lost hours and expensive samples.
- The UV resistant acrylic enclosure provides a contained, dead air space in which to set up your reactions and permits safe 254nm UV irradiation of solutions and supplies. This powerful UV wavelength renders DNA contaminants biologically inactive in 30 minutes or less.
- The thick front panel is an effective beta irradiation shield as well as acting as a breath guard. An overhead fluorescent light illuminates the work area.
- Dimensions: 18"L x 24"W x 28"H
- 1 year warranty
AlumaSeal® CS™
- Specially formulated for cold storage to -80 °C
- Excellent barrier properties to retard evaporation
- Easily pierceable with pipet tips or robotic probes for sample recovery
The Rotocycler 72 facilitates the handling and insertion of caps on the tubes by offering a special solid aluminum loading rack. This rack can hold up to 18 x 0.1 mL tube strips for a total of 72 tubes. Other cavities can hold larger reaction tubes. To keep reactions cool during setup, simply place the rack in a refrigerated area. For easy reference, all wells are numbered. Color coding is made possible by inserting a Capinsert in up to two locations on the rack.
Includes: Rotocycler 72 and 500 assorted color coding inserts
Accessories for the Rotocycler 72
T319-4N |
Rotocycler 0.1 mL Tube and Cap Strips for Qiagen Rotor-Gene Q |
T319-72D2 |
Rotocycler 72 Rotor with 100 µL wells for Qiagen Rotor-Gene Q |
T319-100D1 |
Rotocycler 100 Rotor with 25 µL wells for Qiagen Rotor-Gene Q |
FoilSeal™ RollMate™ Dispenser +1 Roll of FoilSeal™ Film, 500 Pre-Scored Sheets
- Certified DNase- & RNase- free
- Pierceable with a pipet tip or robotic probe for direct sample recovery
- 2.0mil aluminum foil removes easily without tearing
- The conformable nature of foil allows for the visual verification of the seal’s security around each well
- Not recommended for long-term cold storage
- PCR
- Light sensitive assays
- Short-term storage
- Robotics
- -20°C to +120°C
- End-tab removal before thermal cycling is highly recommended
- Remove diagonally from a corner to prevent tearing
ThermalSeal® 2™ and ThermalSeal® Advanced Sealing Film
- Certified DNase- & RNase- free
- Ideal for use with flat-top, semi-skirted and full-skirted PCR plates
- Compatible with hard-shell dual component (e.g. polycarbonate/polypropylene) PCR plates
- Large cut allows for easier positioning of the film to the plate via edge of plate alignment vs. centering
- Available in a smaller cut for raised-rim and non-skirted PCR plates: ThermalSeal® Advanced
- PCR
- -40°C to +120°C
- Selection of the proper film size will minimize evaporation
- The film should not overhang or ride up the wall of a raised-rim plate
- More complete coverage of skirted flat-top plates will reduce evaporation in the outer wells
- End-tab removal before thermal cycling is highly recommended
AbsorbMax™ Black Vinyl Sealing Film for Black Microplates
AbsorbMax™ is a black vinyl film that can be applied to either the top or bottom of the plate.- Minimizes background fluorescence and cross talk between plate wells
- Ideal as a back seal for black plates with clear well bottoms for top reading measurements
- Absorbs stray light, reducing the background caused by light scatter
- Protects light sensitive samples from degradation
- Features a single split liner for easy application
Applications
- Fluorescence assays
- Light sensitive sample protection
Temperature Range
- -40°C to +80°C